نتایج جستجو برای: flattening filter

تعداد نتایج: 127226  

Journal: :Medical physics 2014
Mårten Dalaryd Tommy Knöös Crister Ceberg

PURPOSE There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality ...

Journal: :Journal of Applied Clinical Medical Physics 2015

2016
Jason Cashmore

As the use of linear accelerators operating in flattening filter-free (FFF) modes becomes more widespread, it is important to have an understanding of the surface doses delivered to patients with these beams. Flattening filter removal alters the beam quality and relative contributions of low-energy X-rays and contamination electrons in the beam. Having dosimetric data to describe the surface do...

2017
J. S. Estepa Jiménez M. Díaz Lagos S. A. Martinez-Ovalle

Different types the spectrum of photons were studied; they were emitted from the flattening filter of a LINAC Varian 2100 C/D that operates at 15 MV. The simplified geometry of the LINAC head was calculated using the MCNPX code based on the studies of the materials of the flattening filter, namely, SST, W, Pb, Fe, Ta, Al, and Cu. These materials were replaced in the flattening filter to calcula...

Journal: :Indian Journal of Pure & Applied Physics 2023

This investigation aimed to measure and commission small unflat photon beams using the detectors described in our previous study10. Furthermore, dosimetric parameters of small-field flat were compared provide a better interpretation beam energy spectrum. The TrueBeam linear accelerator (TrueBeam LINAC, Varian Medical Systems) was employed this study. 10 6 MV used output factor, depth dose, prof...

Journal: :Physics in medicine and biology 2009
Stephen F Kry Rebecca M Howell Jerimy Polf Radhe Mohan Oleg N Vassiliev

The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید