نتایج جستجو برای: glassy carbon electrode

تعداد نتایج: 341395  

2016
Katja Magdić Višnja Horvat-Radošević Krešimir Kvastek

Different types of charge storage mechanisms at unmodified graphite vs. glassy carbon electrodes in acid sulphate supporting solution containing potassium hexacyanoferrate (II) redox active electrolyte, have been revealed by electrochemical impedance spectroscopy and supported by cyclic voltammetry experiments. Reversible charge transfer of Fe(CN)6 redox reaction detected by assessment of CVs o...

Journal: :applied biotechnology reports 0
maryam iman fariba dashtestani zahra zafari mehdi kamali manizheh ramezani khadijeh eskandari

graphene modified glassy carbon electrodes have been developed for the determination of calcium dobesilate in pharmaceutical formulations. the prepared graphene and cnts were used as a conductive substrate for electrochemical study of calcium dobesilate. the direct electrochemistry of calcium dobesilate showed a reversible cyclic voltammogram with a formal potential of 133 mv (vs. ag/agcl) for ...

Journal: :Physical chemistry chemical physics : PCCP 2015
Luciana Vieira Robert Schennach Bernhard Gollas

The interface of a 1 : 2 molar choline chloride/ethylene glycol deep eutectic solvent with a glassy carbon electrode has been investigated by polarization modulation reflection-absorption spectroscopy (PM-IRRAS). Temporal spectral changes at open circuit potential show the experiments to be surface sensitive and indicate slow adsorption of electrolyte molecules on the electrode surface. In situ...

2005
Osamu Ikeda Kumiko Yoshinaga Jianping Lei

Trace amounts of nitric oxide (NO) have been determined in aqueous phosphate buffer solutions (pH=7.4) by using a glassy carbon electrode coated with three charge-different polymer films. The glassy carbon electrode was coated first with negatively charged Nafion film containing tetrakis(pentafluorophenylporphyrin) iron(III) chloride (Fe(III)TPFPP) as the NO oxidation catalyst, and then with po...

2008
S Radha Jeyalakshmi S Senthil Kumar

Dopamine, uric acid and ascorbic acid have been determined simultaneously on a poly(3,4-ethylenedioxythiophene) modified electrode using electrochemical techniques. On a bare glassy carbon electrode, all three undergo oxidation and appear as a single peak at around 200 mV, whereas on the modified electrode, distinct peaks with clear potential separation are observed, paving way for their simult...

2013
XIAO-QIN XIONG KE-JING HUANG CHUN-XUAN XU CHUN-XUE JIN QIU-GE ZHAI

A novel electrochemical sensor poly(taurine)/TiO2-graphene nanocomposite modified glassy carbon electrode (PT/TiO2-Gr/GCE) was fabricated. This sensor was based on an electrochemically polymerized taurine layer on a TiO2-graphene modified glassy carbon electrode. The electrochemical behavior of acetaminophen and caffeine at the modified electrode was studied by cyclic voltammetry and differenti...

Journal: :analytical and bioanalytical chemistry research 0
mahmoud roushani department of chemistry, university of ilam, ilam, iran somayeh farokhi department of chemistry, university of ilam, ilam, iran

a simple and reliable electrochemical sensor based on cobalt oxide nanoparticles modified glassy carbon electrode (gce/cooxnps) for determination of butylated hydroxyanisole is presented here. the nanoparticles were fabricated by electrodepositing method. the modified electrode shows excellent catalytic activity toward butylated hydroxyanisole oxidation in ph 12.0 phosphate buffer solution (pbs...

Journal: :Frontiers in bioscience : a journal and virtual library 2005
Qiang Zhao Dongping Zhan Hongyang Ma Meiqin Zhang Yifang Zhao Ping Jing Zhiwei Zhu Xinhua Wan Yuanhua Shao Qiankun Zhuang

A novel glassy carbon electrode modified by a gel containing multi-walled carbon nanotubes (MWNTs) and ionic liquid of 1-butyl-3-methylimidazolium hexafluorophosphate (BMIPF6) is reported. The gel is formed by grinding of MWNTs and BMIPF6. Such gel is then coated on the surface of a glassy carbon electrode. We have employed scanning electron microscopy, Fourier transform infrared spectrometry (...

2012
Sushil Kumar Victoria Vicente-Beckett

Multiwalled carbon nanotubes were used to modify the surface of a glassy carbon electrode to enhance its electroactivity. Nafion served to immobilise the carbon nanotubes on the electrode surface. The modified electrode was used to develop an analytical method for the analysis of ascorbic acid (AA) by square-wave voltammetry (SWV). The oxidation of ascorbic acid at the modified glassy carbon el...

Over the past years, DNA biosensors have been developed to analyze DNA interaction and damage that have important applications in biotechnological researches. The immobilization of DNA onto a substrate is one key step for construction of DNA electrochemical biosensors. In this report, a direct approach has been described for immobilization of single strand DNA onto carboxylic acid-functionalize...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید