Journal: :iranian journal of medical physics 0
mehrdad gholami department of medical physics & radiation sciences, school of para medicine sciences, lorestan university of medical sciences, khorram abad, iran fataneh nemati science & research branch, islamic azad university, tehran, iran vahid karami department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, iran

introduction in radiography, dose and image quality are dependent on radiographic parameters. the problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...

Journal: :iranian journal of medical physics 0
peyman hejazi medical physicist, department of pharmacology and medical physics, faculty of medicine, semnan university of medical sciences

introduction the main goal of this study was to perform quality control test on all radiography units operating in golestan province of iran. materials and methods forty-four x-ray units were examined based on general accepted programs for quality control. eight parameters including kvp accuracy, kvp reproducibility, ma-time reciprocity, exposure linearity, exposure reproducibility, timer accur...

2014
Kanan Jassal Anusheel Munshi Biplab Sarkar Sayan Paul Aman Sharma Bidhu Kalyan Mohanti Arun Chougule Kanupriya Sachdev

Purpose: Evaluation of the newly integrated system for its validation and designing a quality assurance frame work to assess its geometrical, radiological and mechanical accuracy. Methods: Isocentric accuracy of two independent imaging modalities, kV based ExacTrac and MV based iViewGT was evaluated using Winston-Lutz test. A pelvic humanoid phantom was used for the radiological end-to-end test...

Alireza Khoshbin Khoshnazar Milad Mokhtarian Peyman Hejazi, Shahin Nooshi

Introduction The main goal of this study was to perform quality control test on all radiography units operating in Golestan province of IRAN. Materials and Methods Forty-four X-ray units were examined based on general accepted programs for quality control. Eight parameters including kVp accuracy, kVp reproducibility, mA-time reciprocity, exposure linearity, exposure reproducibility, timer accur...

2014
Pei Nie Haiou Li Yanhua Duan Ximing Wang Xiaopeng Ji Zhaoping Cheng Anbiao Wang Jiuhong Chen

PURPOSE To compare the image quality and diagnostic accuracy between sinogram affirmed iterative reconstruction (SAFIRE) algorithm and filtered back projection (FBP) reconstruction algorithm at 70 kVp-tube-voltage DSCT angiography in children with congenital heart disease (CHD). MATERIALS AND METHODS Twenty-eight patients (mean age: 13 months; range: 2-48 months; male: 16; female: 12; mean we...

2016
Kevin A. Wunderle Joseph T. Rakowski Frank F. Dong

The first goal of this study was to investigate the accuracy of the displayed reference plane air kerma (Ka,r) or air kerma-area product (Pk,a) over a broad spectrum of X-ray beam qualities on clinically used interventional fluoroscopes incorporating air kerma-area product meters (KAP meters) to measure X-ray output. The second goal was to investigate the accuracy of a correction coefficient (C...

Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...

Journal: :journal of dentistry, tehran university of medical sciences 0
mahdieh dehghani rasool barzegari hosein tabatabai sahar ghanea

objectives: this study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries. materials and methods: fifty extracted human premolars and molars were mounted in a silicone block. charge-coupled device (ccd) and photostimulable phosphor plate (psp) receptors and intra-oral films were exposed with 60 and 70 kvp wit...

2011
Ahmad Nobah Belal Moftah Nada Tomic Slobodan Devic

Impact of the various kVp settings used during computed tomography (CT) simulation that provides data for heterogeneity corrected dose distribution calculations in patients undergoing external beam radiotherapy with either high-energy photon or electron beams have been investigated. The change of the Hounsfield Unit (HU) values due to the influence of kVp settings and geometrical distribution o...

2017
Mahdieh Dehghani Rasool Barzegari Hosein Tabatabai Sahar Ghanea

OBJECTIVES This study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries. MATERIALS AND METHODS Fifty extracted human premolars and molars were mounted in a silicone block. Charge-coupled device (CCD) and photostimulable phosphor plate (PSP) receptors and intra-oral films were exposed with 60 and 70 kVp wit...