نتایج جستجو برای: maldi toftof

تعداد نتایج: 7959  

2009
J. Wichmann F. Schwaneberg A. Lindinger

In our group, we perform successfully MALDI by using femtosecond laser techniques in order to examine the ionization process. One recent result is MALDI with ultrashort laser pulses in the near IR (central wavelength of =800 nm) [2]. In this wavelength regime, used matrix substances have no absorption bands. Experiments with different laser pulse durations suggest that multi photon ionization i...

Journal: :Journal of clinical microbiology 2015
Costas C Papagiannitsis Vendula Študentová Radoslaw Izdebski Olga Oikonomou Yvonne Pfeifer Efthimia Petinaki Jaroslav Hrabák

A comparison of a matrix-assisted laser desorption ionization-time of flight mass spectrometric (MALDI-TOF MS) meropenem hydrolysis assay with the Carba NP test showed that both methods exhibited low sensitivity (approximately 76%), mainly due to the false-negative results obtained with OXA-48-type producers. The addition of NH4HCO3 to the reaction buffer for the MALDI-TOF MS assay dramatically...

Journal: :Journal of combinatorial chemistry 2003
Andreas H Franz Ruiwu Liu Aimin Song Kit S Lam Carlito B Lebrilla

The identification of pharmacologically promising compounds (lead compounds) from combinatorial libraries is frequently limited by the throughput of the analytical technique employed. Fourier transform mass spectrometry (FTMS) offers high sensitivity, mass accuracy (m/Deltam > 500 000), and sequencing capabilities. A rapid and efficient method for high-throughput analysis of single beads from p...

Journal: :Polymer Chemistry 2021

MALDI-MS using colloidal graphite matrix doped with lithium chloride for the successful analysis of low molecular weight polymers.

Journal: :Journal of proteome research 2003
John A McLean David H Russell

Sensitivity and detection limit enhancements are obtained for peptides by performing high repetition rate (150 Hz) matrix-assisted laser desorption/ionization (MALDI) coupled with ion mobility-time-of-flight mass spectrometry. Absolute limits of detection (3sigma) for model peptides are on the order of 0.1 fmol of peptide deposited and represent a factor of 40-60 improvement over data obtained ...

Journal: :Lab on a chip 2005
Monica Brivio Niels R Tas Martijn H Goedbloed Han J G E Gardeniers Willem Verboom Albert van den Berg David N Reinhoudt

The integration of a monitoring port along the microfluidic path of a MALDI-chip integrated device is described. Optimization of the microreactor design allows longer reaction and measuring times. The Schiff base reaction between 4-tert-butylaniline (1) and 4-tert-butylbenzaldehyde (2) in ethanol was carried out on-chip in the MALDI ionization chamber and the formed imine 3 was detected in real...

Journal: :Trends in biotechnology 2000
L Li R W Garden J V Sweedler

Matrix-assisted laser desorption-ionization (MALDI) mass spectrometry (MS) is a rapid and sensitive analytical approach that is well suited for obtaining molecular weights of peptides and proteins from complex samples. MALDI-MS can profile the peptides and proteins from single-cell and small tissue samples without the need for extensive sample preparation, except for the cell isolation and matr...

Journal: :Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 2013
Maciej Lalowski Fulvio Magni Veronica Mainini Evanthia Monogioudi Athanasios Gotsopoulos Rabah Soliymani Clizia Chinello Marc Baumann

Matrix-assisted laser desorption ionization (MALDI)-profiling and imaging mass spectrometry are promising technologies for measuring hundreds of different molecules directly on tissues. For instance, small molecules, drugs and their metabolites, endogenous lipids, carbohydrates and complex peptides/proteins can be measured at the same time without significant disruption of sample integrity. In ...

2016
Matthias Holzlechner Sonja Reitschmidt Sabine Gruber Susanne Zeilinger Martina Marchetti‐Deschmann

Studying microbial interactions by MALDI mass spectrometry imaging (MSI) directly from growing media is a difficult task if high sensitivity is demanded. We present a quick and robust sample preparation strategy for growing fungi (Trichoderma atroviride, Rhizoctonia solani) on glass slides to establish a miniaturized confrontation assay. By this we were able to visualize metabolite distribution...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید