نتایج جستجو برای: peek

تعداد نتایج: 1857  

2015
D. Almasi S. Izman M. Sadeghi N. Iqbal F. Roozbahani G. Krishnamurithy T. Kamarul M. R. Abdul Kadir

Polyether ether ketone (PEEK) is considered the best alternative material for titanium for spinal fusion cage implants due to its low elasticity modulus and radiolucent property. The main problem of PEEK is its bioinert properties. Coating with hydroxyapatite (HA) showed very good improvement in bioactivity of the PEEK implants. However the existing methods for deposition of HA have some disadv...

2016
C.L. Brockett S. Carbone A. Abdelgaied J. Fisher L.M. Jennings

Total joint replacement is a successful surgical intervention for the treatment of the degeneration of many joints, particularly the hip and knee. As the demand for joint replacement grows, and the life expectancy of the population increases, the performance requirements of these implants also changes. New materials, to improve longevity and enhance performance have been explored including PEEK...

Journal: :Biomaterials 2010
Huaiyu Wang Ming Xu Wei Zhang Dixon T K Kwok Jiang Jiang Zhengwei Wu Paul K Chu

Poly aryl-ether-ether-ketone (PEEK) is an alternative to metal alloys in orthopedic applications. Although the polymer provides many significant advantages such as excellent mechanical properties and non-toxicity, it suffers from insufficient elasticity and biocompatibility. Since the elastic modulus of diamond-like carbon (DLC) is closer to that of cortical bone than PEEK, the DLC/PEEK combina...

Journal: :Journal of materials science. Materials in medicine 2014
Jasmin Waser-Althaus Achim Salamon Marcus Waser Celestino Padeste Michael Kreutzer Uwe Pieles Bert Müller Kirsten Peters

Polyetheretherketone (PEEK) generally exhibits physical and chemical characteristics that prevent osseointegration. To activate the PEEK surface, we applied oxygen and ammonia plasma treatments. These treatments resulted in surface modifications, leading to changes in nanostructure, contact angle, electrochemical properties and protein adhesion in a plasma power and process gas dependent way. T...

2017
Erik A. B. Hughes Liam M. Grover

BACKGROUND Calcium sulphate (CS) has been used in bone grafting since the 1800s. It has not replaced autograft as the gold standard, however, since its dissolution occurs rapidly in bodily fluids, meaning that the material cannot support long-term bone growth. Here, the polymer poly (ether ether ketone) (PEEK) was used to slow dissolution in in vitro physiological environments and augment the m...

Journal: :Acta biomaterialia 2015
Nathan T Evans F Brennan Torstrick Christopher S D Lee Kenneth M Dupont David L Safranski W Allen Chang Annie E Macedo Angela S P Lin Jennifer M Boothby Daniel C Whittingslow Robert A Carson Robert E Guldberg Ken Gall

Despite its widespread clinical use in load-bearing orthopedic implants, polyether-ether-ketone (PEEK) is often associated with poor osseointegration. In this study, a surface-porous PEEK material (PEEK-SP) was created using a melt extrusion technique. The porous layer was 399.6±63.3 μm thick and possessed a mean pore size of 279.9±31.6 μm, strut spacing of 186.8±55.5 μm, porosity of 67.3±3.1% ...

2015
Zongshuang Cao Li Qiu Yongzhen Yang Yongkang Chen Xuguang Liu

The effects of surface modifications of multi-walled carbon nanotubes (MWCNTs) on their dispersibility in different solvents and poly (ether ether ketone) (PEEK) have been studied. MWCNTs were treated by mixed acids to obtain acid-functionalized MWCNTs. The acid-functionalized MWCNTs were modified with six different chemical agents separately, 1,6-diaminohexane, hexadecyl trimethyl ammonium bro...

Journal: :Journal of biomedical materials research. Part B, Applied biomaterials 2017
Jae Hyup Lee Hae Lin Jang Kyung Mee Lee Hae-Ri Baek Kyoungsuk Jin Jun Hong Noh

PEEK is a bioinert material that does not chemically bind to native bone tissue and thus formation of natural bone-like hydroxyapatite (HA) coating layer on PEEK has been an important challenge to improve biocompatibility and to preserve mechanical property of PEEK. Among various coating techniques, cold-spray coating method is suitable to form stable HA coating layer on PEEK while maintaining ...

2012
Xiaomian Wu Xiaochen Liu Jie Wei Jian Ma Feng Deng Shicheng Wei

BACKGROUND Compared with titanium (Ti) and other metal implant materials, poly(ether-ether ketone) (PEEK) shows outstanding biomechanical properties. A number of studies have also reported attractive bioactivity for nano-TiO(2) (n-TiO(2)). METHODS In this study, n-TiO(2)/PEEK nanocomposites were prepared, taking advantage of the unique properties of both PEEK polymer and n-TiO(2). The in vitr...

Journal: :Journal of orthopaedic research : official publication of the Orthopaedic Research Society 2012
Ichiro Nakahara Masaki Takao Tomoyo Goto Chikara Ohtsuki Shigeru Hibino Nobuhiko Sugano

Despite the excellent osseointegration of carbon-fiber-reinforced polyetheretherketone (CFR/PEEK) with a surface hydroxyapatite (HA) coating, the bone-implant interfacial shear strength of HA-coated CFR/PEEK after osseointegration is unclear. We examined the interfacial shear strength of HA-coated CFR/PEEK implants after in vivo implantation in a rabbit femur-implant pull-out test model. HA coa...

نمودار تعداد نتایج جستجو در هر سال