نتایج جستجو برای: power transformer

تعداد نتایج: 494887  

2013
E. Babu R. Subramanian

This project presents reactive power compensation in a distribution power system. DSTATCOM (distribution static compensator) is a reactive power compensator for power quality improvement in a three phase four wire distribution system. A voltage source converter (VSC) based DSTATCOM with a zig-zag transformer is used for the compensation of reactive power for voltage regulation along with load b...

2007
A. M. Niknejad M. Bohsali E. Adabi B. Heydari

A new approach for power combining several low-voltage CMOS amplifiers using a new on-chip transmission line transformer structure is presented. The power combiner utilises the interconnection of short sections of integrated differential lines and has an efficiency independent of the transformation ratio. Full-wave electromagnetic simulation confirms the operation and low insertion loss of the ...

2007
V. Malathi N. S. Marimuthu

This study presents a novel technique based on Support Vector Machine (SVM) for the classification of transient phenomena in power transformer. The SVM is a powerful method for statistical classification of data. The input data to this SVM for training comprises fault current and magnetizing inrush current. SVM classifier produces significant accuracy for classification of transient phenomena i...

2003
John H. Brunke Klaus J. Fröhlich

Transformer inrush currents are highmagnitude, harmonic-rich currents generated when transformer cores are driven into saturation during energization. These currents have undesirable effects, including potential damage or loss-of-life to the transformer, protective relay misoperation, and reduced power quality on the system. Controlled transformer switching can potentially eliminate these trans...

2011
M. Heindl M. Beltle M. Reuter D. Schneider S. Tenbohlen D. T. Oyedokun C. T. Gaunt

Geomagnetically Induced Currents (GIC) are supposed to be a threat to power transformers worldwide. Recent surveys show correlation between solar storm activities, the cause of GIC, and transformers failing within a relatively short time period. The scope of this contribution is to create and investigate a laboratory setup emulating GIC effects by injecting DC currents into a three phase power ...

2014
Antônio Flavio Licarião Nogueira

The study introduces the detailed sequence of operations necessary to determine the selfand mutual inductances of power transformers from numerically simulated open-circuit and bucking experiments. Parameters of a welding style transformer are compared to those of a normal step-down transformer of equivalent ratings. The investigation identifies the different patterns of magnetic flux circulati...

2016
Mohammad Bakhshipour Farhad Namdari Mohammad Sedaghat

Among the most noticeable root causes of improper performance in power transformers, internal short circuit faults can be noted and if not quickly be identified and addressed in the accepted time interval, irrecoverable damages such as interruption or even collapse of the network connected to the power transformer would happen. In this contribution, three-phase transformer behaviors under magne...

2016
A. Rahmati

Power transformers are protected by different relays that operate independently. Malfunction of each relay has a major role in reducing the reliability of the protection system. In order to mitigate the main drawbacks of the power transformer relays, an overall protection scheme is presented in this paper. This scheme proposes a novel multi criterion algorithm using decision-making based on fuz...

Frequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. Various mechanical faults with different ‎extents on power transformers are required to aid FRA ‎interpretation. To address this challenge, in...

2009
Chang-Hung Hsu Yeong-Hwa Chang

In this paper, the properties of the physical and chemical materials, such as low loss amorphous HB1 core, high temperature resistance winding and insulation vegetable oil have been developed for use in liquid-immersed power transformer. The measured results of magnetic properties with different ferromagnetic materials core were obtained. Considering winding property for operation above 95°C co...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید