نتایج جستجو برای: power transformer

تعداد نتایج: 494887  

2006
Ray-Lee Lin Hsu-Ming Shih Chen-Yao Liu Kuo-Bin Liu

CONDUCTION-MODE VOLTAGE SOURCE CHARGE-PUMP POWER FACTOR CORRECTION ELECTRONIC BALLAST * Ray-Lee Lin, Hsu-Ming Shih, National Cheng Kung University, Tainan, Taiwan Chen-Yao Liu, Kuo-Bin Liu, National Synchrotron Radiation Research Center, Hsinchu, Taiwan Abstract This paper presents the piezoelectric transformer (PT) based continuous-conduction-mode (CCM) voltage source (VS) charge-pump (CP) pow...

2008
Feng LV Hao Sun Zhan-feng Wang Yuan LI

As the fault information of power transformers has characteristics such as complementarities, redundancy and uncertainty, the diagnosis task can’t be finished by the simple fault characteristic vector and the diagnosis method. The basic ideas of information fusion are introduced, and DGA (the Dissolved Gas Analysis) is combined tightly with other information such as the results of conventional ...

2014
Enrico Macrelli Aldo Romani Ningning Wang Saibal Roy Michael Hayes Rudi P. Paganelli Marco Tartagni

This paper presents the design of a 1 : 50 bondwire micro-transformer assembled with IC gold bonding wires and a toroidal LTCC magnetic core with race-track shape. The transformer is fabricated on-top of a standard BCD IC in a 15 mm footprint area for micro-power energy harvesting applications. Measurements show a secondary self-inductance up to 29 μH with a maximum Q-factor of 11.6 at 1.3 MHz,...

M. Ghazavi Dozein M. Oskuoee S.M. Abasi V. Gholamrezaie,

In order to reduce the volume and size of distribution power transformer, precise and extended controlling of transformer output, the conventional transformers are replaced by intelligent universal transformers (IUTs). In this paper, an IUT, typical of Iran national grid, with the voltage ratio of 20kV:380 V is designed and simulated. Regarding the IUT implementation, a cascaded H-bridge invert...

2016
M. Gopila I. Gnanambal

Power transformers in transmission network are utilized for increasing or decreasing the voltage level. Power Transformers fail to connect directly to the consumers that result in the less load fluctuations. Power transformer operation under any abnormal condition decreases the lifetime of the transformer. Power Transformer protection from inrush and internal fault is critical issue in power sy...

2017

Abstract—In this paper, the equivalent circuit of the ideal singlephase power transformer with its appropriate voltage current measurement was presented. The calculated values of the voltages and currents of the different connections single phase normal transformer and the results of the simulation process are compared. As it can be seen, the calculated results are the same as the simulated res...

2009
Piush Verma Yog Raj Sood Jashandeep Singh

Transformer is one of the most important and costly apparatus in a power system. The reliable and efficient fault free operation of transformer has a decisive role in the availability of electricity supply. In recent years, there has been growing interest in the condition assessment of transformer insulation. In this paper we concerned about the condition monitoring of transformer, benefit of c...

2013
Mohd Zaifulrizal ZAINOL Nasrudin ABD. RAHIM Jeyraj SELVARAJ

A loosely contactless transformer with a large air gap has small magnetizing inductance and large leakage inductance comparing with a closely conventional transformer. This paper focus on analysis, design and measurement results of the loosely winding contactless transformer using resonant converter. Finally, the experimental set up is built to transfer power of 300 W over the different gap var...

2017
Wenping Cao Jiangfeng Zhang

High power and high voltage gain DC-DC converters are key to high-voltage DC (HVDC) power transmission for offshore wind power. This paper presents an isolated ultra-high step-up DC-DC converter in matrix transformer configuration. A flyback-forward converter is adopted as the power cell and the secondary side matrix connection is introduced to increase the power level and to improve fault tole...

2007
ZHAO YANLEI JIANG ZHIHAI LIU WEI

This paper introduces a high precise direct current (DC) negative high voltage power supply. The supply’s output voltage is 25kV and its maximal output current is 100mA. The power supply uses BOOST converter for power factor correction and voltage regulation. It converts DC to high frequency (HF) alternating current (AC) square wave with phase-shifted full bridge. The voltage of the AC square w...