نتایج جستجو برای: propped cantilever nanoplate

تعداد نتایج: 5422  

2009
Tarsicio Beléndez Cristian Neipp

"Large and small deflections of a cantilever beam".Large and small deflections of a cantilever beam". ABSTRACT The classical problem of deflection of a cantilever beam of linear elastic material, under the action of an external vertical concentrated load at the free end, is analyzed. We present the differential equation governing the behaviour of this physical system and show that this equation...

2014

Experimental results show that specifi c binding between a ligand and surface immobilized receptor such as hybridization of single-stranded DNA (ssDNA) immobilized on a microcantilever surface leads to cantilever defl ection. The binding induced defl ection may be used as a method for detection of biomolecules, such as pathogens and biohazards. Mechanical deformation induced because of hybridiz...

Journal: :Sensors 2019

2006
Nardo Ramírez Frómeta

An increasing number of recent reports confirm the potential of MC sensors for environmental and biomedical applications, and the multifaceted functionality of MCs indicates their uniqueness as compared with more traditional sensor designs. Unlike many other types of transducers for chemical sensors, MCs are simple mechanical devices. They are tiny plates or leaf springs, typically 0.2-1 ìm thi...

2015
Anastasios Badarlis Axel Pfau Anestis Kalfas

Measurement of gas density and viscosity was conducted using a micro-cantilever beam. In parallel, the validity of the proposed modeling approach was evaluated. This study also aimed to widen the database of the gases on which the model development of the micro-cantilever beams is based. The density and viscosity of gases are orders of magnitude lower than liquids. For this reason, the use of a...

2013
Jiayun Zhang Hans Peter Lang Felice Battiston Natalija Backmann Francois Huber Christoph Gerber

A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the ...

2012
S. Subhashini A. Vimala Juliet

A study about the piezoresistive Micro-Electro-Mechanical Systems (MEMS) cantilever for a chemical sensitive mass based sensor has been carried out to enhance sensor sensitivity. The sensitive region attracts the CO2 molecules there by introducing the stress concentration region (SCR). Three types of SCR geometry designs were first analysed using Intellisuite software to study the effect of str...

2013
Jannis Lübbe Matthias Temmen Sebastian Rode Philipp Rahe Angelika Kühnle Michael Reichling

The noise of the frequency-shift signal Δf in noncontact atomic force microscopy (NC-AFM) consists of cantilever thermal noise, tip-surface-interaction noise and instrumental noise from the detection and signal processing systems. We investigate how the displacement-noise spectral density d(z) at the input of the frequency demodulator propagates to the frequency-shift-noise spectral density d(Δ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید