نتایج جستجو برای: ray Computed Tomography Patient Dose Radiation Dosimetry Radiation Dosage

تعداد نتایج: 1653173  

Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

Journal: :journal of biomedical physics and engineering 0
a janbabanezhad-toori school of medicine, babol university of medical sciences, babol, iran a shabestani-monfared department of medical physics, faculty of medicine, babol university of medical sciences, babol, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences) m r deevband department of medical physics, school of medicine, shahid beheshti university of medical sciences, tehran, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences) r abdi department of radiology, mazandaran university of medical sciences, sari, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی شهید بهشتی (shahid beheshti university of medical sciences) m nabahati department of radiology, babol university of medical sciences, babol, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مازندران (mazandaran university of medical sciences)

background : medical x-rays are the largest man-made source of public exposure to ionizing radiation. while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk-free. ct is a device with higher patient dose in comparison with other conventional radiation procedures. objective: this study is aimed at evaluating radiation dose to patients from...

Journal: :Journal of plastic, reconstructive & aesthetic surgery : JPRAS 2009
Warren M Rozen Iain S Whitaker Damien L Stella Timothy J Phillips Paul F Einsiedel Rafael Acosta Mark W Ashton

Table 1 Radiation dose (and comparative background radiation exposure) associated with various imaging techniques, including plain-film x-rays, computed tomography (CT) scans and computed tomography angiography (CTA) scans. Exposure calculated with ImPACT CT Patient Dosimetry Calculator (Version 0.99w, ImPACT, St. George’s The radiation exposure of Computed Tomographic Angiography (CTA) in DIEP...

Journal: :iranian journal of radiology 0
chih-chen chang department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan yon-cheong wong department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan; department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan cheng-hsien wu department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan huan-wu chen department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan li-jen wang department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan yu-hsien lee department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan

conclusion attending radiologists could diagnose acute appendicitis accurately on ne-ldct. performance of senior residents on ne-ldct is better than junior residents and comparable to attending radiologists. results diagnostic performances for acute appendicitis were not statistically different for attending radiologists at both examinations. better performance was noted on the ce-sdct with a b...

2005

The unique radiation exposure conditions that exist in computed tomography (CT), during which thin slices of the patient are irradiated by a narrow, fan-shaped beam of x rays emitted from the x-ray tube during its rotation around the patient, have required the use of special dosimetry techniques to characterize the radiation doses to patients and to monitor CT system performance. This section d...

Journal: :iranian journal of radiation research 0
a. janbabanezhad-toori radiobiology and radiation protection, babol university of medical sciences, babol, iran m.r. deevband department of medical physics and biomedical engineering, school of medicine, shahid beheshti university of medical sciences, tehran, iran a. shabestani-monfared department of medical physics, faculty of medicine, babol university of medical sciences, babol, iran r. abdi department of radiology, mazandaran university of medical sciences, sari, iran m. nabahati department of radiology, babol university of medical sciences, babol, iran

background: computed tomography (ct) is main contributor of population dose from diagnostic x-ray examinations. children are more radiosensitive than adults, thus optimization of ct examination in these patients is essential. the purpose of this study was to evaluate dose delivered to pediatric patients’ undergoing ct examination of the common examinations and also establishing local diagnostic...

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

Fatemeh Sadat Ghoreshi Issac Shiri Jaber Beik Keikhosro Keshavarzi Seyed Rabee Mahdi Mahdavi

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

Journal: :iranian journal of science and technology (sciences) 2008
m. j. butson

– gafchromic xrct radiochromic film is a self developing high sensitivity radiochromic filmproduct which can be used for assessment of delivered radiation doses which could match applications suchas computed tomography (ct) dosimetry. the dose response of gafchromic xrct radiochromic film hasbeen measured with reflectance spectrophotometry and desktop scanners. the film automatically changescol...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید