نتایج جستجو برای: satellite heat pipe design

تعداد نتایج: 1234411  

2018
Donghuan Liu Jing Zhang

High-temperature thermal contact resistance (TCR) plays an important role in heat-pipe-cooled thermal protection structures due to the existence of contact interface between the embedded heat pipe and the heat resistive structure, and the reduction mechanism of thermal contact resistance is of special interests in the design of such structures. The present paper proposed a finite element model ...

2013
Evelyn Wang Daniel Hanks Don Strahan

A manufacturing process plan was developed for a welded condenser utilizing a sintered wick. Electronic devices have progressed to the point where new designs are limited by the thermal management system used to ensure safe operating temperatures. Coupling the effects of high surface area of multiple condensers, the low thermal resistance of loop heat pipes, and the increased dissipation rates ...

2015
Liu Jun Zhang Xu Gao Jun Yang Jie

Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates ...

The forced convective heat transfer (CHT) coefficient of a particular nanofluid, Al2O3 nanoparticles-ethylene glycol (EG) mixture, was investigated experimentally in a double-pipe heat exchanger. The nanofluid Nusselt number for different nanoparticles’ concentrations as well as various operating temperatures was measured to be increased up to 23.7% using 1.0% wt of nanoparticles. The significa...

2006
I. Zervantonakis

The ground thermal properties and the heat-transfer efficiency of the borehole heat exchanger (BHE) system are key parameters for designing ground-coupled systems. Proper design of such systems requires good knowledge of these parameters, providing an efficient and economic operation. For this purpose a test procedure known as Thermal Response Test (TRT) was developed in 1996 at the Oklahoma St...

2013
M Kun Lei Hongfang Ma Haitao Zhang Weiyong Ying Dingye Fang

This paper reported an experimental research of steady-state heat transfer behaviour of a gas flowing through a fixed bed under the different operating conditions. Studies had been carried out in a fixed-bed packed methanol synthesis catalyst percolated by air at appropriate flow rate. Both radial and axial direction temperature distribution had been investigated under the different operating c...

Journal: :E3S web of conferences 2021

Pulsating heat pipe(PHP) has many advantages, such as small volume, simple structure, low cost, good transfer performance, it have great potential in the application of refrigeration, aerospace, waste recovery and - grade energy utilization. Based on analysis a large number research results at home abroad, status pulsating pipe technology is summarized this paper, which can provide scientific g...

Journal: :transport phenomena in nano and micro scales 2014
r. aghayeri h. maddah f. ashori m. aghili

in this work, the characteristics of flow and heat transfer of a fluid containing nano particles of aluminum oxide with the water volume fraction (0.1-0.2-0.3)(v/v) percent of the reports. the overall heat transfer coefficient, heat transfer and the average heat transfer fluid containing nano water - aluminum oxide in a horizontal double pipe counter flow heat exchanger under turbulent flow con...

Journal: :Advances in transdisciplinary engineering 2022

This paper proposes a scheme for creating low-pressure environment to evaporate large amount of water, using the latent heat water evaporation cooling, designing and building test bench pipe air conditioning system, testing working performance negative pressure evaporating conditioner at 30–85°C. COMSOL Multiphysics Establish fluid transfer model analyze internal transfer. Under design conditio...

2001
Tom Webb

In accordance with 10 CFR 50, Appendix A, General Design Criteria 4, the Nuclear Management Company, LLC, (NMC) requests Nuclear Regulatory Commission (NRC) review and approval to exclude the dynamic effects associated with postulated pipe ruptures from the Kewaunee Nuclear Power Plant (KNPP) licensing basis. This request is for portions of the KNPP Residual Heat Removal (RHR), Accumulator Inje...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید