Tomoya Takasago Tomohiro Goto Keizo Wada Daisuke Hamada Toshiyuki Iwame Tetsuya Matsuura Akihiro Nagamachi Koichi Sairyo

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...

Journal: :Orthopedics 2012
Stephanie W Mayer Samuel S Wellman Michael P Bolognesi David E Attarian

This article describes a case of late locking mechanism failure and disassociation of a Pinnacle acetabular cup (DePuy, Warsaw, Indiana) and Marathon polyethylene liner (DePuy) 53 months after routine primary total hip arthroplasty in an active patient. Following an uncomplicated initial postoperative recovery, the patient felt a pop while kneeling for gardening activities. The patient had no p...

Journal: :The Journal of arthroplasty 2014
Trevor C Gascoyne Richard M Dyrkacz Thomas R Turgeon Colin D Burnell Urs P Wyss Jan-M Brandt

Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from ...

2016
Shunsuke Kawano Motoki Sonohata Masaru Kitajima Masaaki Mawatari

Liner dissociation of polyethylene from a cementless acetabular socket following total hip arthroplasty (THA) is a rare complication. Cross-linked polyethylene liner dissociation from AMS-HA shell (KYOCERA Med, Osaka, Japan) occurred in 2 out of the 4153 (0.04%) cases approximately 10 years after undergoing surgery at our institute. First case was an 80-year-old female who underwent right THA a...

Liner design is becoming an increasingly more important tool for the AG/SAG mill performance optimization. The Gol-E-Gohar iron ore concentration plant uses three 9 m × 2.05 m autogenous mills (AG) in parallel in a dry operation. Due to large variations in feed characteristics and inadequate blending, the performance of AG mills has been lower than the target value. In order to increase the cir...

2011
J. Geringer B. Boyer F. Farizon

In hip implants, UHMWPE (Ultra High Molecular Weight Polyethylene) liner wear is believed to be a key issue affecting the lifetime of the artificial joint. Dual mobility, a THA (Total Hip Arthroplasty) concept where the liner moves inside the metallic shell, has become popular due to its low dislocation rate. To understand the tribological behavior of this particular implant, especially the rol...

Journal: :Orthopedics 2014
Michael M Morlock Florian Witt Nick Bishop Rainer Behn Paolo Dalla Pria Rob Barrow Ian Dymond

Third-generation composite ceramics (eg, Delta; DePuy Orthopaedics, Warsaw, Indiana; Ceramtec, Plochingen, Germany) have greatly improved material characteristics compared with second-generation products. This case report presents a patient after total hip arthroplasty with a fractured ceramic liner and a heavily worn ceramic head (both third-generation ceramics) retrieved 9 months after surger...

Journal: :Revista espanola de cirugia ortopedica y traumatologia 2015
A Espinosa-Ruiz P Zorrilla-Ribot J A Salido-Valle

OBJECTIVE In uncemented revision total hip replacement due to polyethylene wear, the metal cup needs to be maintained when its stability is checked during surgery, only replacing the polyethylene that is cemented if anchoring is not possible. The aim of the present study was to evaluate the medium-term clinical and radiological results of a polyethylene liner cemented into an osseointegrated ac...

A. Merati Z. Soltani S. Ali S.A. Hosseini Kordkheili

Thermal buckling behavior of truncated conical liner reinforced by laminated composite is investigated in the presence of a general initial imperfection. For this purpose, the method of virtual work and first-order strain-deformation shell theory are employed to extract equilibrium equations. To this end, a finite element code is developed using the 3D 8-node shell element with six degrees of f...

2010
Jiri Kunecky Ondrej Jirousek

The probability of brain injury during an accident is dependent on the force history acting on brain tissue. The mostly used criterion for the injury probability assessment, the Head Injury Criterion (HIC), is based on the time integral of force (acceleration) history curve. HIC is used in the work for the assessment of helmet performance. Because of limited weight of the helmet, current design...