نتایج جستجو برای: shell liner

تعداد نتایج: 55664  

Journal: :The Journal of bone and joint surgery. British volume 2009
A H Krieg B M Speth P E Ochsner

Polyethylene wear of acetabular components is a key factor in the development of periprosthetic osteolysis and wear at the articular surface has been well documented and quantified, but fewer data are available about changes which occur at the backside of the liner. At revision surgery for loosening of the femoral component we retrieved 35 conventional modular acetabular liners of the same desi...

Journal: :Journal of physics 2023

Abstract In order to further improve the flight stability of explosively formed projectile, formation method tail EFP was studied based on polygonal liner. Under hexagonal charge structure, fins can be when structural parameters are matched. Through numerical simulation LS-DYNA, influence liner (curvature radius, linear thickness), height and shell thickness velocity, length-diameter ratio, com...

Journal: :The Journal of bone and joint surgery. British volume 1991
R J Beaver E H Schemitsch A E Gross

We report a case of late dissociation of a one-piece metal-backed acetabular component, associated with a prolific soft-tissue reaction to the polyethylene debris. The polyethylene liner was not visible on the radiographs. The metal-backed shell could not be removed because of bone ingrowth. We recommend that modular systems be utilised in cementless arthroplasty of the hip and that radiographi...

Journal: :Aviation, space, and environmental medicine 1978
K J Saczalski E Q Richardson

A nonlinear, finite-element, model is used to examine the biodynamic impact response to helmeted and unhelmeted headforms having human response characteristics. The human response headform is modeled as a spherical brain of nearly incompressible material, a covering of linear elastic dura, a linear elastic spherical skull, and a layer of nonlinear scalp material. The helmet system is modeled as...

Journal: :The Journal of bone and joint surgery. British volume 2004
P Duffy J L Sher P F Partington

The ABG I cementless hip prosthesis has demonstrated unacceptably high rates of wear and osteolysis in our patients. We performed a retrospective study of 97 hips implanted between 1992 and 1998. Radiographic analysis revealed high rates of wear of the polyethylene liner with marked peri-acetabular osteolysis. Clinical examination indicated that many of these patients were initially asymptomati...

Journal: :Clinical Orthopaedics and Related Research® 2009

Journal: :The Journal of bone and joint surgery. British volume 1993
R L Barrack D W Burke S D Cook H B Skinner W H Harris

We report complications from the use of modular components in 20 hip replacements in 18 patients. Fifteen complications (in 13 patients) were related to failure of a modular interface after operation. Femoral head detachment from its trunnion was seen in 6 hips from trauma (3), reduction of a dislocation (2), and normal activity (1). In one case the base of the trunnion fractured below an extra...

2016
Ana Laura Puente Reyna Marcus Jäger Thilo Floerkemeier Sven Frecher Karl-Stefan Delank Christoph Schilling Thomas M Grupp

Backside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination ...

Journal: :The Journal of bone and joint surgery. British volume 2010
E W Patten S A Atwood D W Van Citters B A Jewett L A Pruitt M D Ries

Retrieval studies of total hip replacements with highly cross-linked ultra-high-molecular-weight polyethylene liners have shown much less surface damage than with conventional ultra-high-molecular-weight polyethylene liners. A recent revision hip replacement for recurrent dislocation undertaken after only five months revealed a highly cross-linked polyethylene liner with a large area of visible...

Journal: :The Journal of arthroplasty 1997
V G Williams L A Whiteside S E White D S McCarthy

Locking mechanisms and metal-liner interface surfaces of six modular acetabular systems were evaluated to determine their effect on micromotion and backside wear of the polyethylene liner. Rotational and axial motion between the metal shell and polyethylene liner was measured in the Duraloc (DePuy, Warsaw, IN), Harris-Galante (Zimmer, Warsaw, IN), Impact (Biomet, Warsaw, IN), Lip Loc (Biomet), ...