نتایج جستجو برای: spectrophotometric error
تعداد نتایج: 266402 فیلتر نتایج به سال:
Simple, easy to use and selective method of Al(III) sorption-spectroscopic (SS) determination was proposed. For this purpose, silica modified with tridecyloctadecylammonium chloride(SGII) using adsorption technique and glass slide modified with thin silica-poly(dimethyldiallyl-ammonium chloride) (SGI) composite film obtained by sol-gel technique were worked out. It was shown that lumogallion (L...
A spectrophotometric recycling assay for the quantitation of L-phenylalanine (and phenylpyruvate) has previously been reported (Cooper et al., Anal. Biochem. 183, 210-214, 1989). The procedure involves the coupling of bacterial phenylalanine dehydrogenase with rat kidney cytosolic glutamine transaminase K. The latter enzyme possesses high affinity for phenylpyruvate. Recycling results in a > or...
DESPITE THE NUMEROUS procedures available for the determination of uric acid, their clinical use remains subject to considerable error. A simple precise method for routine clinical use is desirable since determination of the level of serum uric acid is an important criterion for the diagnosis of gout. Excellent critical reviews of the available methods have been published (1, 2, 3). The current...
The most common spectrophotometric reagents employed for the determination of titanium (IV) are hydrogen peroxide[1] and tiron[2]. However, N-benzoylN-phenylhydroxylamine[3,4] and N-phenyllaurohydroxamic acid[5] are introduced for extractive spectrophotometric determination of titanium (IV). Aroylhydraones such as pyridoxal salicyloylhydrazone[6], diphenylglyoxal bis (benzoylhydrazone)[7] and d...
This paper describes zeroand first-order derivative spectrophotometric methods for determination of estradiol valerate in pharmaceutical preparations. The solutions of the standard and pharmaceutical samples were prepared in methanol. Absorbances of estradiol valerate were measured at 280 nm for zero-order by measuring height of peak from zero, at 292 nm for first-order derivative spectrophotom...
Simple, fast and reliable derivative spectrophotometric methods were developed for determination of olanzapine in bulk and pharmaceutical dosage forms. The solutions of standard and the sample were prepared in methanol. The quantitative determination of the drug was carried out using the first derivative values measured at 222 nm and the second derivative values measured at 230 nm (n=6). Calibr...
Non-derivative and derivative UV spectrophotometric techniques using water as solvent have been developed for the simultaneous determination of amoxicillin and clavulanate in combined tablets. For UV spectrophotometric techniques, the concentrations of amoxicillin and clavulanate in conformity with the Lambert-Beer law are 100.0 – 160.0 mg/ml and 10.0 – 35.0 mg/ml, respectively. The derivative ...
A. Introduction B. Optical and Spectrophotometric Detectors 1. Differential refractometry 2. Ultraviolet spectrophotometry 3. Fluorescence detection 4. Infrared spectrophotometric detectors 5. Spectrophotometric detection with post-column chemical reaction C. Some Miscellaneous Detection Systems 1. The mass spectrometer as an HPLC detector 2. Radioactivity detectors 3. Density, electrochemical ...
to assess the pollution trend of southwest ground water aquifer of tehran by nitrite and nitrate, in february 1999, out of 300 wells within this area, 99 wells were selected according to simple random sampling without replacement, analysed by colorimetric and ultraviolet spectrophotometric screening standard methods, respectively. the conclusion asserted is that with a confidence limit of 95%, ...
Ten per cent of the general adult population have a diagnosable personality disorder (Zimmerman & Coryell, 1990)and in 4% this is clinically severe (Tyrer, 1988). The clinical management of such patients may be difficult. However, much clinical difficulty is generated by interpersonal aspects deriving from the particular interaction of the patient and psychiatrist involved and the respec tive r...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید