نتایج جستجو برای: thermoluminescent dosimetry

تعداد نتایج: 8409  

2000
M. R. O. O. Silva F. D. G. Rocha J. C. Bressiani

INTRODUCTION The thermoluminescent (TL) properties of various materials have been studied since a long time but many of these developments never reach the thermoluminescent dosimeter (TLD) users. α-Al2O3:C TL detectors were first developed and produced at Urals Polytechnical Institute ( UPI ) (1) in the form of a single crystal. These TLD ( model 2600 – 80 ) are now supplied by Victoreen to man...

Journal: :Physics in medicine and biology 2000
M J Butson R Elferink T Cheung P K Yu M Stokes K Y Quach P Metcalfe

Verification of calculated lung dose in an anthropomorphic phantom is performed using two dosimetry media. Dosimetry is complicated by factors such as variations in density at slice interfaces and appropriate position on CT scanning slice to accommodate these factors. Dose in lung for a 6 MV and 10 MV anterior-posterior field was calculated with a collapsed cone convolution method using an ADAC...

Journal: :Brachytherapy 2014
Joshua L Reed Mark J Rivard John A Micka Wesley S Culberson Larry A DeWerd

PURPOSE To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of a new elongated (103)Pd brachytherapy source through both experimental measurements and Monte Carlo (MC) simulations. Measured and MC-calculated dose distributions were used to determine the American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters for t...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
Martin J Butson Tsang Cheung Peter K N Yu Sian Price Michael Bailey

Accurate measurement and knowledge of dose delivered under eye shield during superficial X-ray radiotherapy is required for patient peripheral dose assessment. Critical structures can include the cornea, lens and retina. Measurement of dose under eye shields has been historically performed with Thermoluminescent Dosimeters (TLD's) due to their small size and design. Restrictions include the ene...

Journal: :Clinical radiology 2004
D J McLaughlin R B Mooney

AIM To assess the effectiveness and economy of routinely using commercially available in-plane bismuth shielding during CT scanning of the chest and brain. METHODS AND MATERIALS Forty patients were scanned with thermoluminescent dosemeters (TLDs) in situ to measure the radiation dose to the thyroid and eye during CT scanning of the brain and chest. Half of the patients had the "AttenuRad" shi...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi medical physics department, medical physics research center, mashhad university of medical sciences, mashhad, iran.

introduction the present work describes a study in which, based on patient dose measurements, thermoluminescent dosimeters were used to obtain the diagnostic reference level arising from panoramic radiography. materials and methods ten panoramic units and a sample of 15 patients per x-ray unit were studied. two thermoluminescent dosimeter chips were placed on the skin surface of selected organs...

Journal: :Radiologia brasileira 2016
Beatriz de Lucena Villa-Chan Cantalupo Aline Carvalho da Silva Xavier Clemanzy Mariano Leandro da Silva Marcos Ely Almeida Andrade Vinícius Saito Monteiro de Barros Helen Jamil Khoury

OBJECTIVE To estimate the entrance surface air kerma (Ka,e) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. MATERIALS AND METHODS Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the...

Journal: :Sarcoma 2004
M. V. Williams N. G. Burnet E. Sherwin R. Kestelman A. R. Geater S. J. Thomas C. B. Wilson

Purpose. Following limb conserving surgery for bone or soft tissue sarcoma, patients may require post-operative radiotherapy to minimise the risk of local recurrence. In such circumstances the metal prosthesis reduces the dose in its shadow by approximately 10% when using opposed fields. We describe a technique to boost the underdosed area to overcome this problem.Patients or subjects. Seven se...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید