نتایج جستجو برای: thermoluminescent dosimetry

تعداد نتایج: 8409  

Journal: :Silicon 2021

The thermoluminescence technique was employed to study bioglass matrix prepared using the traditional of glass making. synthesized were investigated X-ray diffraction (XRD), and differential thermal analysis (DTA) has been studied. highest thermoluminescent intensity found for composition 26.91 % CaO, 45.68 SiO2, 2.50 P2O5, 25.094 %Na2O (mol%), with only one glow peak at 460 k. TL response illu...

2010
L.A.R. da Rosa S.C. Cardoso L.T. Campos V.G.L. Alves D.V.S. Batista A. Facure

The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF:Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical alg...

2015
Raffaele Liuzzi Federica Savino Vittoria D’Avino Mariagabriella Pugliese Laura Cella Gabriele Multhoff

BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for qua...

2004
M. Hajek T. Berger N. Vana

At high altitudes in the Earth’s atmosphere cosmic-ray induced neutrons become the dominant contributors to the biologically relevant dose equivalent. Depending on the geomagnetic latitude and the solar activity cycle, neutron dose onboard aircraft amounts to about 50 to 70 % of the overall dose equivalent. Neutron detection in complexly mixed radiation environments by means of active, i.e. pow...

2011
Pooneh Saidi Mahdi Sadeghi S. Hamed Hosseini Claudio Tenreiro

This work presents experimental dosimetry results for a new 103Pd brachytherapy seed, in accordance with the AAPM TG-43U1 recommendation that all new low-energy interstitial brachytherapy seeds should undergo one Monte Carlo (MC) and at least one experimental dosimetry characterization. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermo...

Journal: :Nuclear Technology & Radiation Protection 2021

Passive solid state dosimeters, such as thermoluminescence provide integrated measurement of the total dose and are widely used in environmental monitoring programs. The objective this paper is to a comprehensive review on use thermoluminescent dosimetry methods for radiation environment. article presents part research results project PREPAREDNESS (EMPIR 2016 call Metrology Environment joint pr...

Journal: :Physics in medicine and biology 2009
G Massillon-Jl R Minniti M G Mitch M J Maryanski C G Soares

Absorbed dose distributions in 3D imparted by a single (90)Sr/(90)Y beta particle seed source of the type used for intravascular brachytherapy were investigated. A polymer gel dosimetry medium was used as a dosemeter and phantom, while a special high-resolution laser CT scanner with a spatial resolution of 100 microm in all dimensions was used to quantify the data. We have measured the radial d...

2008
Peter L. Roberson Jean M. Moran Ravi Kulasekere

Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work...