نتایج جستجو برای: titanium alloy

تعداد نتایج: 83904  

2009
Su-Sung Kim Mong-Sook Vang Hong-So Yang Sang-Won Park Hyun-Pil Lim

STATEMENT OF PROBLEM The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND METHODS Disks of commercially...

Journal: :Dental materials journal 2004
Shinji Takemoto Masayuki Hattori Masao Yoshinari Eiji Kawada Katsuhiko Asami Yutaka Oda

The purpose of this study was to investigate the correlation between corrosion resistance and surface composition of an experimental Ti-20 mass% Cr casting alloy in a saline solution containing fluoride. The alloy had a greater resistance to corrosion in a fluoride-containing saline solution than did commercially pure titanium. However, with confirmed dissolution of titanium and chromium, it me...

2012
Abdo Bachoura Ruriko Yoshida Christian Lattermann Srinath Kamineni

A retrospective review of 21 patients that underwent bone screw removal from the elbow was studied in relation to the type of metal, duration of implantation, and the location of the screws about the elbow. Screw failure during extraction was the dependent variable. Five of 21 patients experienced hardware failure during extraction. Fourteen patients had titanium alloy implants. In four cases, ...

2016

This article presents the mechanical properties and microstructure of titanium alloy after selective laser melting (SLM). Titanium alloys are ideal material for selective laser melting (SLM), because they are expensive and difficult to machinery using traditional technologies. The application of SLM in the biomedical area has been slow due to the stringent performance criteria and concerns rela...

2007
Masafumi Morita Tokiko Hashimoto Kiyoshi Yamauchi Yuji Suto Takayuki Homma Yuji Kimura

This study was conducted to evaluate the biocompatibility of titanium-nickel shape memory alloy used as a medical implant material. The authors carried out the following electrochemical corrosion test and in vivo and in vitro biological tests for the alloy and some metal and alloys clinically used previously to compare the intensities concerned with the biological reactions, that is, (1) anodic...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شهید باهنر کرمان 1387

چکیده ندارد.

Journal: :International journal of molecular medicine 2012
Yongping Wang Zhaojin Zhu Yaohua He Yao Jiang Jian Zhang Jialin Niu Lin Mao Guangyin Yuan

The neotype magnesium alloy, Mg-Nd-Zn-Zr (NZK) alloy, was implanted into the rabbit femur to investigate its in vivo degradation behavior and biocompatibility. Seventy-two New Zealand white rabbits were randomly divided into the NZK alloy group, titanium alloy group and sham-operated group. Then NZK alloy rods were embedded in the rabbit femur in the NZK alloy group, titanium alloy rods were em...

2015
Min Lai Xiaofang Yang Qing Liu Jinghua Li Yanhua Hou Xiuyong Chen Kaiyong Cai

To investigate the effect of surface nanostructures on the behaviors of human umbilical vein endothelial cells (HUVECs), surface nanostructured titanium alloy (Ti-3Zr2Sn-3Mo-25Nb, TLM) was fabricated by surface mechanical attrition treatment (SMAT) technique. Field emission scanning electron microscopy (FE-SEM), atomic force microscopy (AFM), transmission electron microscopy (TEM) and X-ray dif...

2008
C. N. Elias

Materials used for biomedical applications cover a wide spectrum and must exhibit specific properties. The most important property of materials used for fabricating implants is biocompatibility, followed by corrosion resistance. The main metallic biomaterials are stainless steels, cobalt alloy, and titanium and titanium alloys. Stainless steel was the first metallic biomaterial used successfull...

2013
Dongmei Ye Yiming Xu Han Zhang Tengfei Fu Lan Jiang Yuehong Bai

BACKGROUND Microwave is a method for improving fracture repair. However, one of the contraindications for microwave treatment listed in the literature is surgically implanted metal plates in the treatment field. The reason is that the reflection of electromagnetic waves and the eddy current stimulated by microwave would increase the temperature of magnetic implants and cause heat damage in tiss...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید