نتایج جستجو برای: titanium alloy

تعداد نتایج: 83904  

2016
Weifang Zhang Yuanxing Huang Wei Dai Xiaoshuai Jin Chang Yin

Titanium screws have properties that make them ideal for applications that require both a high strength-to-weight ratio and corrosion resistance, such as fastener applications for aviation and aerospace. The fracture behavior of Ti-10Mo-8V-1Fe-3.5Al (TB3) alloy screws during assembly was explored. Besides visual examination, other experimental techniques used for the investigation are as follow...

Journal: :Journal of the mechanical behavior of biomedical materials 2012
L Bolzoni P G Esteban E M Ruiz-Navas E Gordo

The applicability of irregular prealloyed Ti-6Al-4V powder for the fabrication of titanium products by pressing and sintering and its employment as a master alloy to obtain the Ti-3Al-2.5V alloy was studied. To this end, the starting powders were characterised by dilatometry, differential thermal analysis and XRD. Green samples were obtained by cold uniaxial pressing, and the evolution of the m...

2018
Xiao-Bo He Tao Ma Wei Zheng Qing-He Geng Kai-Jin Guo

Aseptic loosening of artificial joints is the leading cause of failure for patients who receive total joint arthroplasty. Prior reports indicate that bone marrow mesenchymal stem cells (BSMC) are critical in the stabilization of implanted artificial joints, and that deregulated interaction between BMSCs and artificial joint derived particles is a risk factor for aseptic loosening with an unknow...

2005
Ikuo Ihara

This paper presents a newly developed high temperature ultrasonic sensor and its application to in situ observation of aluminum (Al) alloy during solidification and melting in temperature up to 800C. The ultrasonic sensor mainly consists of a conventional piezoelectric transducer, a titanium buffer rod as an acoustic waveguide and an air cooling pipe. The length is approximately 300 mm. This ul...

2017
Yangju Feng Wencong Zhang Li Zeng Guorong Cui Wenzhen Chen

In this paper, the microstructure, the room-temperature and high-temperature tensile mechanical properties of monolithic TA15 alloy and TiB whisker-reinforced TA15 titanium matrix composites (TiBw/TA15) fabricated by vacuum hot-pressing sintering were investigated. The microstructure results showed that there were no obvious differences in the microstructure between monolithic TA15 alloy and Ti...

Journal: :AJNR. American journal of neuroradiology 2003
Frank G Shellock Jean A Tkach Paul M Ruggieri Thomas J Masaryk Peter A Rasmussen

BACKGROUND AND PURPOSE The use of 3.0-T MR systems is increasing worldwide. We evaluated magnetic field interactions and translational attraction for 32 aneurysm clips in association with exposure to "long-bore" and "short-bore" 3.0-T MR imaging systems. METHODS Thirty-two different aneurysm clips were evaluated in this investigation. Each aneurysm clip was qualitatively evaluated for magneti...

Journal: :The European journal of prosthodontics and restorative dentistry 2007
Nathan K C Luk Victor H F Wu Bernard M H Liang Ya-Ming Chen Kevin H K Yip Roger J Smales

AIMS To establish the minimum dimensions for a non-precious cast metal occlusal rest by using mathematical analysis. An occlusal rest in a removable partial denture (RPD) provides vertical support and allows occlusal forces to be transmitted through the long axis of the abutment tooth. METHODS The stress status of an occlusal rest in a posterior tooth-bounded RPD resembles that of a cantileve...

Journal: :The Journal of bone and joint surgery. British volume 1992
J M Lee E A Salvati F Betts E F DiCarlo S B Doty P G Bullough

Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from...

2013
M. Pakshir M. R. Kazemi

Orthodontic mechanotherapy encompasses the use of several archwires during speci c stages of treatment. Metallic orthodontic appliances consist of bands, arch wires, ligature wires, hooks, tubes, brackets, and springs are daily used in orthodontic practices for the correction of malocclusions in patients ( Oh et al. , 2004 ; Verstrynge et al. , 2006 ; Sabane et al. , 2009 ). One of the most im...

Journal: :Nanotoxicology 2017
A Besinis S D Hadi H R Le C Tredwin R D Handy

One of the most common causes of implant failure is peri-implantitis, which is caused by bacterial biofilm formation on the surfaces of dental implants. Modification of the surface nanotopography has been suggested to affect bacterial adherence to implants. Silver nanoparticles are also known for their antibacterial properties. In this study, titanium alloy implants were surface modified follow...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید