نتایج جستجو برای: tld

تعداد نتایج: 963  

2005
Lorenzo Vega-Montoto Peter D. Wentzell

The implementation of maximum likelihood parallel factor analysis (MLPARAFAC) in conjunction with the direct exponential curve resolution algorithm (DECRA) is described. DECRA takes advantage of the intrinsic exponential structure of some bilinear data sets to produce trilinear data by a simple shifting scheme, but this manipulation generates an error structure that is not optimally handled by ...

2017
TOM LOUCAS GILLIAN BAIRD

Spoken word recognition, during gating, appears intact in specific language impairment (SLI). This study used gating to investigate the process in adolescents with autism spectrum disorders plus language impairment (ALI). Adolescents with ALI, SLI, and typical language development (TLD), matched on nonverbal IQ listened to gated words that varied in frequency (low/high) and number of phonologic...

Journal: :روش های عددی در مهندسی (استقلال) 0
فیاض رحیم زاده روفویی و آرش ملکان f. rahimzadeh rofooei and a. malakan

tuned liquid dampers (tld) are among passive control devices that have been used to suppress the vibration of structures in recent years. these structures must be adequately presentable as an equivalent single degree of freedom system with long fundamental period. the tld, located at the top floors of the structure, can dissipate the external input energy into the system through the sloshing ef...

F. Rahimzadeh Rofooei and A. Malakan,

Tuned Liquid Dampers (TLD) are among passive control devices that have been used to suppress the vibration of structures in recent years. These structures must be adequately presentable as an equivalent single degree of freedom system with long fundamental period. The TLD, located at the top floors of the structure, can dissipate the external input energy into the system through the sloshing ef...

F. Rahimzadeh Rofooei and A. Malakan,

Tuned Liquid Dampers (TLD) are among passive control devices that have been used to suppress the vibration of structures in recent years. These structures must be adequately presentable as an equivalent single degree of freedom system with long fundamental period. The TLD, located at the top floors of the structure, can dissipate the external input energy into the system through the sloshing ef...

Journal: :Gastroenterology & hepatology 2023

Introduction: The most common cancer in women worldwide is breast and radiotherapy the best treatment choice after mastectomy.1,2 In radiation therapy mastectomy, depending on type of tumor, area removed goes under radiotherapy. Methods: TLD (Thermoluminescence Dosimetry) chips were used this project. Typically, each patient an irradiation 200 cGy during 25 sessions received a total 5000 cGy. R...

2012
Martin Raison Botao Hu

This report documents how we improved the TLD framework for real-time object tracking [1] by using a new set of features and modifying the learning algorithm.

One of structural passive control methods is to use Tuned Liquid Damper (TLD). However, because of the nature of the TLD, only one tuning frequency can be created when the water is sloshing. To fix this problem, some installed rotatable baffles can be embedded inside TLD called Variably Baffled TLD (VBTLD) where by changing the angle of the baffles a tuning frequency range is created. This gives ...

Journal: :Viruses 2023

Increased HIV drug resistance (HIVDR) with antiretroviral therapy (ART) rollout may jeopardize therapeutic options, especially in this era of transition to fixed-dose tenofovir-lamivudine-dolutegravir (TLD). We studied acquired HIVDR (ADR) patterns and describe potentially active drugs after first- second-line failure resource-limited settings (RLS) like Cameroon. A laboratory-based study 759 p...

2000
R. P. Stokes L. Talbot

This paper describes preliminary work to develop a cosmic-radiation dosemeter for use by military aircraft crew. The dosemeter is based on a combination of CR-39 etched-track detectors and TLD-700 thermoluminescent detectors. It is intended that the CR-39 be used to assess the neutron dose, while the TLD700 is used to assess the photon and charged particle dose. The sensitivity of CR-39 to the ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید