نتایج جستجو برای: transformer loss

تعداد نتایج: 456485  

2013
Xin-Huai Wang Li Zhang Yin Xu Yan-Fu Bai Cheng Liu Xiaowei Shi

In this paper, a compact tri-band impedance transformer by utilizing stubbed coupling line for matching a load at three arbitrary frequencies is proposed. The transformer is composed of two parts, and each part is constructed from parallel-coupled transmission lines. Two structures with different configurations of the proposed transformer have been given and analyzed. Then, the close-form equat...

2004
M. F. MOHD KAMAL T. K. A. RAHMAN I. MUSIRIN

The increasing demand of electrical power has caused the system network to be in stressed condition which led to transmission loss in the system. Consequently, voltage profile of the system decays accordingly leading to unpredictable voltage instability phenomenon. The issue of loss minimisation has been progressively investigated in the power system environment. Many techniques have been devel...

2001
T. G. Engel

The analysis, design, and operation of high-voltage, transformer-coupled LC vector inversion generators are presented and discussed. The transformer-coupled LC inversion generator is easy to construct and, compared with Marx-type generators and conventional LC vector inversion generators, requires only one inversion switch, independent of the number of voltage multiplication stages. The transfo...

Journal: :Environmental Health Perspectives 1985
H R Buser

In several accidents (fires, explosions) involving electrical systems containing polychlorinated biphenyls (PCBs) or benzenes (PCBZs), the formation of polychlorinated tricyclic aromatic compounds such as polychlorinated dibenzofurans (PCDFs), dibenzo-p-dioxins (PCDDs) and biphenylenes (PCBPs) was observed. These findings were not surprising in light of our previous studies on the formation of ...

2004
Nitin Keshao Dhote D. M. Holey M. R. Ramteke

Power transformer is a vital component of power system, which has no substitute for its major role. They are quite expensive also. It is therefore, very important to closely monitor it’s in – service behavior to avoid costly outages and loss of production. Many devices have evolved to monitor the serviceability of power transformers. These devices such as Buchholz relay or differential relay re...

2000
P. Haldi G. Liu

Introduction: Power amplifiers are a key building block in any radio transceiver, usually necessitating a multi-chip module solution owing to the requirement of a specialised process with high voltage breakdown and low-loss passive components. Several researches have demonstrated that CMOS technology is a viable option for implementation of the power amplifier. Fully integrated transformer base...

2008
Xiao-Yuan Chen Jian-Xun Jin

⎯With the improvement of high temperature superconductor (HTS) practical performance, research and development concerning the applications of HTS transformers have been progressed actively worldwide. This paper provides a comprehensive summary on various HTS transformers, and studies the design of a single-phase 10 kVA (220V/24V) HTS transformer prototype to verify HTS for practical transformer...

2009
C. R. Sullivan Charles R. Sullivan

The number and diameter of strands to minimize loss in a litz-wire transformer winding is determined. With fine stranding, the ac resistance factor can be decreased, but dc resistance increases as a result of the space occupied by insulation. A power law to model insulation thickness is combined with standard analysis of proximity-effect losses to find the optimal stranding. Suboptimal choices ...

Farshad, Moniri,

Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnost...

2012

This paper presents an experimental investigation of transformer dielectric response and solid insulation water content. The dielectric response was carried out on the base of Hybrid Frequency Dielectric Spectroscopy and Polarization Current measurements method (FDS &PC). The calculation of the water content in paper is based on the water content in oil and the obtained equilibrium curves. A re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید