نتایج جستجو برای: آشکارساز hpge

تعداد نتایج: 1884  

Journal: :Processes 2022

In this research, polymers were fabricated through combining polyester, boron oxide (B2O3), and Tellurium (TeO2). B2O3 has good neutron absorption TeO2 is not only highly dense (5.670 g/cm3) but also environment-friendly, compared to PbO, as well being a photon absorber. The radiation protection features for five investigated samples examined utilizing an HPGe detector point sources Am-241, Cs-...

2013
Panakkada Latha K. K Abdullah K. M. Varier

Coherent and incoherent scattering cross section measurements have been carried out using a HPGe detector on elements in the range of Z = 13 50 using Am gamma rays. The cross sections have been derived by comparing the net count rate obtained from the Compton peak of aluminium with the corresponding peak of the target. The measured cross sections for the coherent and incoherent processes are co...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2002
D V Filossofov A F Novgorodov N A Korolev V G Egorov N A Lebedev Z Z Akselrod J Brockmann F Rösch

A new method of the perturbed angular gamma-gamma-correlation (PAC) measurements was developed using one HPGe detector only (1-PAC). For quantifying the perturbation factor, the ratio R gamma 1 + gamma 2 of the summing peak composed of two cascade gamma-rays (the perturbation-affected parameter) to the summing peak composed of one gamma-ray and one X-ray (the perturbation non-affected parameter...

2012
Dariusz Malczewski Jerzy Żaba

The activity concentrations of 40K, 232Th, and 238U in the characteristic rocks of the Modane-Aussois region (Western Alps, France) were determined using an HPGe gamma-ray spectrometry system. The activity concentrations of 40K varied from 18 Bqkg-1 (limestone dolomite) to 392 Bqkg-1 (calcschist), while those of 232Th varied from 0.7 Bqkg-1 (limestone dolomite) to 18 Bqkg-1 (calcschist). The ac...

2016
Magdalena Długosz-Lisiecka

The two counting modes: a normal with a single HPGE detector and second with the additional anti-Compton shield of the annular NaI(Tl) detector have been compared for fast determination of the activity concentration of thorium 232Th in the building materials. The 232Th activity concentration was calculated by measurement of its decay products: 212Pb, 212Bi and 208Tl as well 228Ac content. Altho...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2009
Mikael Hult J S Elisabeth Wieslander Gerd Marissens Joël Gasparro Uwe Wätjen Marcin Misiaszek

The radioactivity of (180m)Ta has never been detected. The present attempt to detect it was carried out using a newly developed HPGe sandwich spectrometer installed 500m water equivalent underground in the HADES laboratory. The sample consisted of 6 discs of tantalum of natural isotopic composition with a total mass of 1500 g and a total mass for (180)Ta of 180 mg. The sample was measured for 6...

2008
S. A. Talha R. J. de Meijer N. A. Mlwilo A. K. Mohanty

Measurement of radon in water by g-ray spectrometry using a HPGe detector has been investigated to determine aquifer characteristics. The radon activity concentration is determined by taking the weighted average of the concentrations derived from g-ray lines associated with Pb and Bi decay. The role of accurate radon data to representatively sample aquifers was also investigated by studying a s...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2000

Journal: :Nuclear Technology and Radiation Protection 2018