نتایج جستجو برای: بلور czt

تعداد نتایج: 2168  

2013
Li Chang Gai Cui

Grating displacement measurement technique is an important means to achieve precise displacement measurement of nanometer scale. Moiré fringe phase difference measurement is the basis of grating displacement measurement technique. Traditional Moiré fringe subdivision method based on DFT algorithm has low frequency resolution relatively when extracting Moiré fringe fundamental frequency spectral...

2001
Aleksey E. Bolotnikov Steven E. Boggs C. M. Hubert Chen Walter R. Cook Fiona A. Harrison Stephen M. Schindler

In this paper we present studies of the I-V characteristics of CdZnTe detectors with Pt contacts fabricated from highresistivity single crystals grown by the high-pressure Brigman process. We have analyzed the experimental I-V curves using a model that approximates the CZT detector as a system consisting of a reversed Schottky contact in series with the bulk resistance. Least square fits to the...

Journal: :European heart journal cardiovascular Imaging 2014
Alessia Gimelli Riccardo Liga Emilio Maria Pasanisi Assuero Giorgetti Gavino Marras Brunella Favilli Paolo Marzullo

AIMS To evaluate the relationships between measures of left ventricular (LV) filling dynamics at cadmium-zinc-telluride (CZT) imaging and indexes of LV diastolic function at transthoracic echocardiography. METHODS AND RESULTS Two hundred and forty-seven patients underwent myocardial perfusion imaging at rest and after stress with a low-dose CZT protocol and a baseline transthoracic echocardio...

2012
Xiaowang Zhou Donald K. Ward Bryan M. Wong F. Patrick Doty Jonathan A. Zimmerman

Cd(1-x)Zn(x)Te (CZT) crystals are the leading semiconductors for radiation detection, but their application is limited by the high cost of detector-grade materials. High crystal costs primarily result from property nonuniformity that causes low manufacturing yield. Although tremendous efforts have been made in the past to reduce Te inclusions/precipitates in CZT, this has not resulted in an ant...

2004
A. E. Bolotnikov G. S. Camarda G. A. Carini G. W. Wright D. S. McGregor W. McNeil R. B. James

New data regarding performance studies of Frisch-grid CdZnTe (CZT) detectors are presented. The Frisch-grid detector configuration under investigation is a bar shaped CZT crystal with the side surfaces coated with an insulating layer. A Frisch grid is fashioned by inserting the CZT bar into a metallic sleeve, or by depositing the metal directly upon the insulator; hence the semiconductor materi...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2003
Bryon Mueller Michael K O'Connor Ira Blevis Deborah J Rhodes Robin Smith Douglas A Collins Stephen W Phillips

UNLABELLED The purpose of this study was to evaluate a small semiconductor-based gamma camera that may have applications in scintimammography. METHODS A small cadmium zinc telluride (CZT) detector was evaluated. The detector had a field of view of 20 x 20 cm with detector elements of 2.5 x 2.5 mm in size. Both short-bore (35 mm) and long-bore (50 mm) collimators, matched to the geometry of th...

2001
José M. Pérez Zhong He David K. Wehe

The single polarity charge sensing method based on coplanar grid electrodes has demonstrated promising results on CZT detectors having volumes of ~1 cm. This paper presents the performance of two coplanar grid CZT detectors having dimensions of 1.5 1 5 1.0 cm2, among the largest CZT spectrometers that have been reported. Energy resolutions of 2.3% and 2.0% full-width half-maximum were obtained ...

2014
A. Pedro Gonçalves Charles Hall David J. Kowbel N. Louise Glass Arnaldo Videira

We pinpoint CZT-1 (cell death-activated zinc cluster transcription factor) as a novel transcription factor involved in tolerance to cell death induced by the protein kinase inhibitor staurosporine in Neurospora crassa. Transcriptional profiling of staurosporine-treated wild-type cells by RNA-sequencing showed that genes encoding the machinery for protein synthesis are enriched among the genes r...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2016
Alban Bailliez Olivier Lairez Charles Merlin Nicolas Piriou Damien Legallois Tanguy Blaire Denis Agostini Frederic Valette Alain Manrique

UNLABELLED This study compared two SPECT cameras with cadmium-zinc-telluride (CZT) detectors to a conventional Anger camera with cardiofocal collimators for the assessment of left ventricular (LV) function in a phantom and patients. METHODS A gated dynamic cardiac phantom was used. Eighteen acquisitions were processed on each CZT camera and the conventional camera. The total number of counts ...

2012
K. K. Patel H. McCabe D. J. Burt K. V. Lever

This paper describes t he design and performance o f c h i r p c o r r e l a t o r s used i n a f e a s i b i l i t y study o f speech t r a n s f o r m coding. Two chips have been evaluated, a 50-point Block CZT processor and a 100-point s l i d i n g CZT processor. The r e l a t i v e m e r i t s of the two systems are compared i n the context of data-compression o f speech s i g n a l s usin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید