نتایج جستجو برای: cobalt alloy

تعداد نتایج: 81530  

Journal: :The Journal of bone and joint surgery. British volume 1974
E M Evans M A Freeman A J Miller B Vernon-Roberts

Loosening of the prosthesis, an important cause of clinical failure following total joint replacement, may be due to faulty implantation of the prosthesis, to trauma, or to infection in the tissues adjacent to the implant. Cases of loosening exist, however, in which the technique of implantation appears to have been satisfactory, in which there is no history of injury and in which there is no e...

Journal: :The Journal of arthroplasty 2014
Trevor C Gascoyne Richard M Dyrkacz Thomas R Turgeon Colin D Burnell Urs P Wyss Jan-M Brandt

Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from ...

2015
Zafar Khan Ghouri Nasser A. M. Barakat Hak Yong Kim

In this study, CoCu alloy nanoparticles-incorporated carbon nanofibers are introduced as effective non precious electrocatalyst for methanol oxidation in alkaline medium. The introduced electrocatalyst has been synthesized by simple and effective process; electrospinning. Typically, calcination, in nitrogen atmosphere, of electrospun nanofibers composed of cobalt acetate, copper acetate and pol...

Journal: :The International journal of oral & maxillofacial implants 2013
Gianluca Paniz Edoardo Stellini Roberto Meneghello Andrea Cerardi Edoardo Alvise Gobbato Eriberto Bressan

PURPOSE The purpose of this study was to investigate the marginal precision of computer numeric control-milled frameworks fabricated of grade 4 commercially pure titanium or cobalt-chrome alloy through digital technology and to compare them with conventional cast frameworks. MATERIAL AND METHODS A titanium cast of a mandibular arch with six implant analogs was used as a master. The master cas...

2017
J. Loch

The work presents the results of the studies of Co-Cr-Mo casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo alloys of different contents of Mo, W and other additives. Electrochemical tests were performed, which aimed at examining the corrosion resistance of the alloys and observing the...

Journal: :Medical device technology 2009
E Keehan C Cavanagh V Gergely

A novel cobalt-chromium (CoCr) based alloy, optimised for speciality needle applications, has been benchmarked against Type 304 stainless steel in a series of mechanical test and experimental needle trials. The results reported indicate that the CoCr alloy has the potential to overcome current limitations in endoscopic and minimally invasive surgery.

Journal: :Journal of international oral health : JIOH 2013
Smita Musani Iqbal Musani Ramandeep Dugal Nitin Habbu Pallavi Madanshetty Danish Virani

BACKGROUND The purpose of this study was to evaluate and compare the micro tensile bond strength of two metal bonding resin cements to sandblasted cobalt chromium alloy. MATERIALS & METHODS Eight, Cobalt chromium alloy blocks of dimensions 10x5x5 mm were cast, finished and polished. One of the faces of each alloy block measuring 5x5mm was sandblasted with 50 μm grit alumina particles. The all...

2016
Chul-Ho Kim Young Hyun Choi Mi Yeon Jeong Jae Suk Chang Pil Whan Yoon

In 1960s, toxic heart failure due to cobalt poisoning was firstly reported from Canadian industrial worker. Following development of bearing materials in hip arthroplasties, using cobalt-chrome alloy in bearing surface, there were rarely reported of systemic affect toxic cobaltism include toxic heart failure due to articulation wear in Western countries. It could be happened more easily by thir...

2009
Su-Sung Kim Mong-Sook Vang Hong-So Yang Sang-Won Park Hyun-Pil Lim

STATEMENT OF PROBLEM The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND METHODS Disks of commercially...

2007
H. Yu Rehan Ahmed H. de Villiers Lovelock S. Davies

(HIPing), can improve the tribo-mechanical properties of cobalt-based alloys. The alloy selected for this investigation had a nominal wt.% composition of Co-30Cr-14W-1C, which is similar to the composition of the commercially available Stellite®4 alloy. The Hot Isostatic Pressed (HIPed) alloy had a much finer microstructure than the cast alloy, which showed a typical hypoeutectic dendritic micr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید