نتایج جستجو برای: ion selective electrode

تعداد نتایج: 450039  

2017
Tanushree Ghosh Hyun-Joong Chung Jana Rieger

Conventional ion-selective electrodes with a liquid junction have the disadvantage of potential drift. All-solid-state ion-selective electrodes with solid contact in between the metal electrode and the ion-selective membrane offer high capacitance or conductance to enhance potential stability. Solution-casted chitosan/Prussian blue nanocomposite (ChPBN) was employed as the solid contact layer f...

E. Baghdar M. Aghaie M. Giahi M. H. Fekri S. Farhadi

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشگاه پیام نور مرکز - دانشکده علوم پایه 1388

در این پایان نامه جهت اندازه گیری پتانسیومتری کاتیونهای سرب pb2+ و نیکلni2+ ، الکترود یون گزین غشایی مبتنی بر پلی وینیل کلرید (pvc) و الکترودهای خمیر کربن با استفاده از دو یون دوست جدید به همراه نرم کننده و افزودنیهای یونی طراحی، ساخت و مورد بررسی قرار گرفت. در تهیه الکترود یون گزین سرب از لیگاند n,n بیس( سالیسیلیدین) 1و6 دی آمینو هگزان (nsah) در ترکیب الکترود خمیر کربنی استفاده شد. الکترود ف...

H. Khanmohammadi H. Shafie M. Darvishpour M. H. Fekri R. Aminameli

A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....

Journal: :physical chemistry research 2015
maryam hosseini bahram ghalami-choobar mohammad ali zanjanchi

in this work, the results concerning to the mean activity coefficient measurements for nacl in the (glycerol + water) system using the potentiometric method are reported. the potentiometric measurements were performed on the galvanic cells without liquid junction of the type: ag|agcl|nacl (m), glycerol (wt%), h2o (1 - wt)%|na-ise, in various mixed solvent systems containing 0, 5, 10, 20 and 30 ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشکده علوم پایه 1388

چکیده ندارد.

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaie karim zare ali reza abedin mehran aghaie

a highly selective electrode for bromide ion based on aza pyrilium derivative as an excellentionophore is described.the sensor exhibits a good linear response with a slope of ( 60±1 ) mv per decadeover the concentration range of ( 1×10-3 – 9×10-6 m ) , and a detection limit of ( 3×10-6 m ) of bromideions .the electrode response is independent of ph in the range of(4.0 –9.5).selectivity coeffici...

2017
Marcel A. G. Zevenbergen

This work presents a flexible miniaturized ion-selective sensor consisting of a solidcontact reference electrode (RE) and ion-selective electrodes (ISE) fabricated on the same foil. The flexible ion sensor was based on AgCl electrodes screen printed on polyethylene terephthalate foil. The RE was formed by casting a mixture of plasticized polyvinylchloride (PVC) and KCl on the AgCl electrode. Th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید