1106 Normal values for strain calculated from velocity encoded MRI

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative assessment of myocardial motion from velocity encoded MRI

Methods 11 Volunteers (30±8 years) and 3 patients (41±11 years) were investigated at a 3T whole body MR scanner (Achieva, Philips) with a 32 channel cardiac coil. The patients suffered from DCM, asynchrony and/or LBBB. A velocity encoded (TPM) navigated segmented gradient echo sequence was applied in the apical, equatorial and basal slice. The acquisition parameters were: FOV=340mm, in-plane re...

متن کامل

Pulmonary pulse wave velocity as assessed with velocity-encoded MRI

Methods In 15 healthy volunteers (7 male; mean±SD age 19±6 years) pulmonary PWV was prospectively assessed between the proximal main pulmonary artery (MPA) and just before the first branching of the distal left pulmonary artery (LPA). One-directional through-plane velocity-encoded (VE) MRI using breath holds was used to assess the pulmonary flow at the levels of MPA and distal LPA with a tempor...

متن کامل

High-resolution, high-SNR velocity maps reconstructed from low-resolution Fourier velocity encoded MRI data

Introduction: Fourier velocity encoding (FVE) provides considerably higher SNR than phase contrast (PC), due to its higher dimensionality and larger voxel sizes. FVE is also robust to partial voluming, as it measures the velocity distribution of the spins within each voxel. FVE data are typically acquired with low spatial resolution, due to scan-time restrictions associated with its higher dime...

متن کامل

Computational fluid dynamics simulations guided by Fourier velocity encoded MRI

Introduction: Fourier velocity encoding (FVE) is a promising MRI method for assessment of cardiovascular blood flow. FVE provides considerably higher signal-to-noise ratio (SNR) than phase contrast (PC) imaging, and is robust to partial-volume effects. On the other hand, FVE does not directly provide velocity maps. These maps are useful for calculating the blood flow through a vessel, or for gu...

متن کامل

Volumetric motion quantification by 3D velocity encoded MRI

Methods 12 volunteers (26±7 years) and 2 patients (46, DCM/29, LBBB) were investigated at a 3T whole body MR scanner (Achieva, Philips) with a 32 channel cardiac coil. A 3D black blood velocity encoded navigated segmented gradient echo sequence (3D-TPM) was applied for whole heart coverage. The acquisition parameters were: FOV=380mm, isotropic resolution of 3x3x3mm, FOV in through-plane directi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance

سال: 2008

ISSN: 1532-429X

DOI: 10.1186/1532-429x-10-s1-a231