1235 High-pass resolution perimetry vs static threshold perimetry in advanced primary open-angle glaucoma
نویسندگان
چکیده
منابع مشابه
1235 High-pass resolution perimetry vs static threshold perimetry in advanced primary open-angle glaucoma
PURPOSE: To compare Static Threshold Perimetry (Humphrey 30.2) with High-pass Resolution Perimetry (Ophthimus) for the assessment of Visual Field W.F.) defects in uatients with advanced glaucomatous damage. METHODS: Patient selection criteria: Primary Open-angle Glaucoma, advanced V.F. damage (MD > 5 dB) visual acuity > 20/70. previous experience in V.F. testing: 38 eyes were selected for the s...
متن کاملCorrelation of Relative Dispersion Analysis and Other High Pass Resolution Perimetry Indices with Standard Threshold Perimetry
Purpose: Relative dispersion analysis (RDA), a new high pass resolution perimetry (HRP) index, appears to capture a novel aspect of visual field abnormality. The aim of this study was to evaluate the correlation of RDA and other HRP indices with the Humphrey perimeter parameters. Methods: Fifty-six eyes were randomly recruited from among patients at the authors’ clinic. Twenty-nine eyes were cl...
متن کاملHigh spatial resolution automated perimetry in glaucoma.
BACKGROUND Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD High spatial resolution perimetry was performed using ...
متن کاملSensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma
Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field ...
متن کاملCLINICAL SCIENCE Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma
Aims: To investigate the agreement in results between frequency doubling technology (FDT) and the conventional automated static perimeter in eyes with normal tension glaucoma (NTG) and high tension glaucoma (HTG). Methods: 72 eyes of 36 patients, who had two or more experiences with the Humphrey field analyser (HFA) program C30-2, were examined with the screening C-20-1 program of FDT. The resu...