A comparative clinical study on the correlation of working length determined using three different electronic apex locators with radiographic working length: An in vivo study

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Efficacy of Three Different Electronic Apex Locators in Comparison with Radiographic Working Length Determination

The aim of this study was to test the efficacy of three different electronic apex locators (EALs) in comparison with the radiographic working length determination. This study was conducted on the 211 root canals of 113 teeth in the undergraduate endodontic clinic. Under the referee of the research assistants, the students determined the working length by taking a periapical radiograph with the ...

متن کامل

in vitro comparison of working length determination using three different electronic apex locators

background: the aim of this study was to compare the accuracy of the apex-locating functions of dentaport zx, raypex 5 and endo master electronic apex locators (eals) in vitro. materials and methods: thirty extracted human single-rooted teeth with mature apices were used for the study. the real working length (rwl) was established by subtracting 0.5 mm from the actual root canal length. all tee...

متن کامل

An in vivo comparative evaluation to determine the accuracy of working length between radiographic and electronic apex locators.

BACKGROUND An in vivo comparative evaluation to determine the accuracy of working length between radiographic and electronic apex locators. AIM The study was aimed at evaluating the accuracy of electronic apex locator, to determine the working length of root canal, and to compare it with the radiographic method of working length determination. MATERIALS AND METHODS A total of 20 teeth selec...

متن کامل

In vitro comparison of working length determination using three different electronic apex locators

BACKGROUND The aim of this study was to compare the accuracy of the apex-locating functions of DentaPort ZX, Raypex 5 and Endo Master electronic apex locators (EALs) in vitro. MATERIALS AND METHODS Thirty extracted human single-rooted teeth with mature apices were used for the study. The real working length (RWL) was established by subtracting 0.5 mm from the actual root canal length. All tee...

متن کامل

Electronic Apex Locators and Conventional Radiograph in Working Length Measurement

The success of endodontic treatment is highly dependent on the adequate three-dimensional cleaning, shaping, disinfection, and obturation of the root canal system. It is universally accepted that the correct determination of the working length (WL) is one of the crucial steps in the process of a successful treatment. It is believed that root canal preparation and filling should be kept inside t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Endodontology

سال: 2016

ISSN: 0970-7212

DOI: 10.4103/0970-7212.184325