A film-type glucose sensor with optical transparency.
نویسندگان
چکیده
منابع مشابه
Continuous blood glucose monitoring with a thin-film optical sensor.
BACKGROUND We recently described a holographic optical sensor with improved selectivity for glucose over fructose that was based on a thin-film polymer hydrogel containing phenylboronic acid receptors. The aim of the present work was to measure glucose in human blood plasma as opposed to simple buffers and track changes in concentration at a rate mimicking glucose changes in vivo. METHODS We ...
متن کاملPrecision optical displacement sensor based on ultra-thin film photodiode type optical interferometers
The design and fabrication of our compact precision optical displacement sensor (PODS) are based on the newly developed ultra-thin film photodiode with its active layer thinner than a half of the incident light wavelength. In this paper, a detailed description of the principle, design, fabrication process and performance of PODS for application in both smooth and rough surfaces will be given.
متن کاملSurface Plasmon Resonance Sensor with Magneto-optical Thin Film
Thanks to resonant excitation of surface plasmons, SPR sensors including ferromagnetic thin films allow the enhancement of the magneto-optical response. MO-SPR structures with Au/Co/Au sandwiches are theoretically analyzed in transverse configuration. The influence of sandwich film thicknesses and layer order is discussed. The optimized geometry and corresponding feedback are specified.
متن کاملThin film composite optical waveguides for sensor applications: a review.
We review the design and fabrication of thin-film composite optical waveguides (OWG) with high refractive index for sensor applications. A highly sensitive optical sensor device has been developed on the basis of thin-film, composite OWG. The thin-film OWG was deposited onto the surface of a potassium-ion-exchanged (K(+)) glass OWG by sputtering or spin coating (5-9mm wide, and with tapers at b...
متن کاملInterferometric optical sensor for measuring glucose concentration.
With a specially designed probe, the phase difference between s andp polarization of light reflected under surface-plasmon resonance is measured by use of a common-path heterodyne interferometer. For specific ratios of phase difference to glucose concentration, the glucose concentration can be estimated as a function of the measured phase data. A prototype was set up to demonstrate the feasibil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Advanced Science
سال: 2002
ISSN: 1881-3917,0915-5651
DOI: 10.2978/jsas.14.33