A light calibration system for the ProtoDUNE-DP detector
نویسندگان
چکیده
منابع مشابه
The MuLan Detector Calibration System
The MuLan experiment has been designed to make a precision measurement of the muon lifetime to one part per million. The experiment uses 340 scintillation detectors to detect the positron produced in the muon's decay. Members of the James Madison University Physics department have been responsible for the design and implementation of a calibration system for the MuLan detector. The calibration ...
متن کاملNovel method for structured light system calibration
Peisen S. Huang, MEMBER SPIE State University of New York at Stony Brook Department of Mechanical Engineering Stony Brook, New York 11794 E-mail: [email protected] Abstract. System calibration, which usually involves complicated and time-consuming procedures, is crucial for any 3-D shape measurement system. In this work, a novel systematic method is proposed for accurate and quick cal...
متن کاملThe MINOS Light Injection Calibration System
A description is given of the light-injection calibration system that has been developed for the MINOS long-baseline neutrino oscillation experiment. The system is based upon pulsed blue LEDs monitored by PIN photodiodes. It is designed to measure non-linearities in the PMT gain curves, as well as monitoring any drifts in PMT gain, at the 1% level.
متن کاملDP: A Detector for Presuppositions in survey questions
This paper describes and evaluates a detector of presuppositions (DP) for survey questions. Incorrect presuppositions can make it difficult to answer a question correctly. Since they can be difficult to detect, DP is a useful tool for questionnaire designer. DP performs well using local characteristics of presuppositions. It reports the presupposition to the survey methodologist who can determi...
متن کاملContinuous System Calibration Using Non-visible Light
With the growing adoption of automatic systems for aligning the geometry of large multi-projector displays in venues such as flight or ship bridge simulators, it has become possible for even the most complicated visual systems to be realigned regularly to maintain seamless geometric alignment. Despite this ability, for the most part, these alignment systems still require that the system be take...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2019
ISSN: 1748-0221
DOI: 10.1088/1748-0221/14/04/t04001