A Nafion®-based co-planar electrode amperometric sensor for methanol determination in the gas phase
نویسندگان
چکیده
منابع مشابه
Platinium-Ruthenium electrocatalyst as sensor electrode for methanol oxidation
Hybrid nanocomposites of binary Pt-Ru/Polyaniline were prepared by oxidative polymerization of aniline andformation Pt and Ru nanoparticles. The polymerization of aniline was carried out in the presence of Potassiumhexa cyano Platinate (IV) and Ruthenium (III) nitrosyl nitrate as oxidizing agents. During the reaction anilinemonomers undergo oxidation and form polyaniline (PANi) whereas the redu...
متن کاملA novel reagentless amperometric immunosensor based on gold nanoparticles/TMB/Nafion-modified electrode.
A novel reagentless immunosensor was fabricated by immobilization of redox mediator 3,3',5,5'-tetramethylbenzidine (TMB) on the Nafion (Nf) film modified glassy carbon electrode. Gold nanoparticles were assembled onto the TMB/Nafion film modified electrode to provide active sites for the immobilization of antibody molecules. The antibody (anti-MIgG), in the present study, was fixed on the elect...
متن کاملAmperometric Sensor Used for Determination of Thiocyanate with a Silver Nanoparticles Modified Electrode
A novel electrode modified with silver nanoparticles was fabricated. It is found that the reducibility of silver nanoparticles is higher than for bulk silver by comparing a silver nanoparticles modified electrode with a silver micro-disk electrode. When SCN was added, a new oxidation peak occurred and the anodic peak current of silver nanoparticles decreased. The new anodic peak current is prop...
متن کاملAMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE
The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...
متن کاملA novel two-enzyme amperometric electrode for lactose determination.
Coimmobilization of beta-galactosidase and glucose oxidase in a redox polymer, polyvinylferrocenium perchlorate (PVF+ ClO4-), led to the development of an enzyme electrode for the determination of lactose. The amperometric response of the electrode was measured at +0.70 V vs. SCE, which was due to the electrooxidation of enzymatically produced H2O2. The effects of the substrate and buffer conce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Chemical Sciences
سال: 2009
ISSN: 0974-3626,0973-7103
DOI: 10.1007/s12039-009-0084-x