A Partial Volume Effect Correction Tailored for 18F-FDG-PET Oncological Studies
We have developed, optimized, and validated a method for partial volume effect (PVE) correction of oncological lesions in positron emission tomography (PET) clinical studies, based on recovery coefficients (RC) and on PET measurements of lesion-to-background ratio (L/B m) and of lesion metabolic volume. An operator-independent technique, based on an optimised threshold of the maximum lesion upt...
متن کاملAccuracy and Precision of Partial-Volume Correction in Oncological PET/CT Studies.
Accurate quantification of tracer uptake in small tumors using PET is hampered by the partial-volume effect as well as by the method of volume-of-interest (VOI) delineation. This study aimed to investigate the effect of partial-volume correction (PVC) combined with several VOI methods on the accuracy and precision of quantitative PET. METHODS Four image-based PVC methods and resolution modeli...
متن کاملA method for model-free partial volume correction in oncological PET
UNLABELLED BACKGROUND As is well known, limited spatial resolution leads to partial volume effects (PVE) and consequently to limited signal recovery. Determination of the mean activity concentration of a target structure is thus compromised even at target sizes much larger than the reconstructed spatial resolution. This leads to serious size-dependent underestimates of true signal intensity ...
متن کاملStatistical Based PET Partial Volume Correction
The partial volume effect in Positron Emission Tomography (PET) is a problem for quantitative radiotracer studies. This effect results from the limited spatial resolution of the imaging device (a few mm’s). Two factors are involved; the spillover of radioactivity into neighbouring regions and the underlying tissue inhomogeneity of the particular region. Linear methods are currently used to corr...
متن کاملPartial Volume Correction in PET/CT
In this thesis, a two-dimensional pixel-wise deconvolution method for partial volume correction (PVC) for combined Positron Emission Tomography and Computer Tomography (PET/CT) imaging has been developed. The method is based on Van Cittert's deconvolution algorithm and includes a noise reduction method based on adaptive smoothing and median filters. Furthermore, a technique to take into account...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BioMed Research International
سال: 2013
ISSN: 2314-6133,2314-6141