A tunable X-ray microprobe using synchrotron radiation
نویسندگان
چکیده
منابع مشابه
ID22: a multitechnique hard X-ray microprobe beamline at the European Synchrotron Radiation Facility.
The ID22 beamline is dedicated to hard X-ray microanalysis allowing the combination of fluorescence, spectroscopy, diffraction and tomography techniques in a wide energy range from 6 to 70 keV. The recent installation of an in-vacuum undulator, a new sample stage and the adaptation of various focusing optics has contributed to a great improvement in the capabilities of the beamline, which is no...
متن کاملContemporary X-ray electron-density studies using synchrotron radiation
Synchrotron radiation has many compelling advantages over conventional radiation sources in the measurement of accurate Bragg diffraction data. The variable photon energy and much higher flux may help to minimize critical systematic effects such as absorption, extinction and anomalous scattering. Based on a survey of selected published results from the last decade, the benefits of using synchro...
متن کاملX-ray synchrotron radiation and particle acceleration
I discuss X-ray synchrotron emission as a probe of particle acceleration, concentrating mainly on low-power (FRI) jets but also touching on the hotspots in FRII sources. Combining X-ray and radio data has allowed us to locate the sites of high-energy particle acceleration, and hence jet kinetic energy dissipation, in a number of objects. Recent data solve some old problems but present some new ...
متن کاملSample environment in experiments using X-ray synchrotron radiation
2014 Modern electron (positron) storage rings are able to emit very intense X-ray radiation with a continuous spectrum extending to 0.1 A, from bending magnets and insertion devices (wavelength shifters and multipole wigglers). It can be used directly for white beam experiments and/or for monochromatic beam experiments with wavelength chosen at will from the continuous spectrum. Another type of...
متن کاملManganese enhanced MRI in rat hippocampus: A correlative study with synchrotron X-ray microprobe
Manganese enhanced MRI (MEMRI) offers many possibilities such as tract tracing and functional imaging in vivo. Mn is however neurotoxic and may induce symptoms similar to those associated with Parkinson's disease (manganism). The mechanisms of Mn-induced neurotoxicity are not clear. In this study, we combine synchrotron X-ray fluorescence microprobe (SR-XRF) and MEMRI techniques to investigate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1990
ISSN: 0168-9002
DOI: 10.1016/0168-9002(90)90050-g