Absolute frequency measurement of the magnesium intercombination transitionS01→P13

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precision frequency measurement of visible intercombination lines of strontium.

We report the direct frequency measurement of the visible 5s(2) 1S0-5s5p 3P1 intercombination line of strontium that is considered a possible candidate for a future optical-frequency standard. The frequency of a cavity-stabilized laser is locked to the saturated fluorescence in a thermal Sr atomic beam and is measured with an optical-frequency comb generator referenced to the SI second through ...

متن کامل

Frequency-comb-referenced two-wavelength source for absolute distance measurement.

We propose a new tunable laser source concept for multiple-wavelength interferometry, offering an unprecedented large choice of synthetic wavelengths with a relative uncertainty better than 10(-11) in vacuum. Two lasers are frequency stabilized over a wide range of frequency intervals defined by the frequency comb generated by a mode-locked fiber laser. In addition, we present experimental resu...

متن کامل

High-precision Absolute Distance Measurement using Frequency Scanned Interferometry

In this letter, we report high-precision absolute differential distance measurements performed with frequency scanned interferometry (FSI). Absolute differential distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer was used to determine frequency changes during scanning. Two new multi-distance-measure...

متن کامل

Absolute frequency measurement of mid-infrared secondary frequency standard at BNM-LPTF

1 Absolute frequency measurement of Mid Infrared secondary frequency standard at BNM-LPTF G. D. Rovera, , Member, IEEE and O. Acef Abstract|An absolute frequency measurement of a CO2=OsO4 secondary frequency standard, operating in the mid infrared, is reported. A brief description of the measurement chain linking this standard to a hydrogen maser evidences the critical points. The measured freq...

متن کامل

the effect of oxytetracycline on serum calcium, phosphorus and magnesium in cattle

نتایج این مطالعه نشان می دهد که مقدار کلسیم (یونیزه و تام)، منیزیم و فسفر به طور معنی داری تغییر پیدا کرد به جزء مقدار کلسیم تام و منیزیم در روش داخل عضلانی که تغییر معنی داری نداشته است. بر اساس نتایج این مطالعه می توان نتیجه گیری کرد که اکسی تتراساکلین بر روی مقادیر سرمی کلسیم و منیزیم تأثیر می گذارد باید مقدار این کاتیون ها در بیماران، در هنگامی که اکسی تتراسایکلین استفاده می شود مورد توجه ق...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review A

سال: 2008

ISSN: 1050-2947,1094-1622

DOI: 10.1103/physreva.78.033830