Accelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction

Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...

متن کامل

Accelerated three-dimensional cine phase contrast imaging using randomly undersampled echo planar imaging with compressed sensing reconstruction.

The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing ...

متن کامل

Accelerated Proton Echo-Planar Spectroscopic Imaging Using Parallel Imaging and Compressed Sensing

INTRODUCTION: Proton Echo-Planar Spectroscopic Imaging (PEPSI) provides fast spatial-spectral encoding and has been demonstrated to map a variety of metabolites in the human brain [1,2]. Further acceleration in PEPSI can be accomplished by using parallel imaging along the phaseencoding dimension(s) [3,4]. However, the acceleration is limited by the relatively low SNR of the metabolites and g-fa...

متن کامل

Accelerated Diffusion Spectrum Imaging with Compressed Sensing Using Adaptive Dictionaries

Diffusion spectrum imaging offers detailed information on complex distributions of intravoxel fiber orientations at the expense of extremely long imaging times (∼1 h). Recent work by Menzel et al. demonstrated successful recovery of diffusion probability density functions from sub-Nyquist sampled q-space by imposing sparsity constraints on the probability density functions under wavelet and tot...

متن کامل

Accelerated 4D flow imaging with variable-density cartesian undersampling and parallel imaging reconstruction

Methods Variable-density Poisson Disk Distribution (VD-PDD) undersampling was applied for 4D flow imaging. By applying VD-PDD independently at each time frame (Figure 1a), we achieved random undersampling in both the ky-kz plane and temporal domains. In addition, we applied an improved initial solution for SPIRIT to significantly improve reconstruction accuracy and robustness. We explored the d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance

سال: 2014

ISSN: 1532-429X

DOI: 10.1186/1532-429x-16-s1-w18