Acceptability of Implantable Continuous Glucose Monitoring Sensor
نویسندگان
چکیده
منابع مشابه
Overview of a novel sensor for continuous glucose monitoring.
The core element of a continuous glucose monitoring (CGM) system is the glucose sensor, which should enable reliable CGM readings in the interstitial fluid in subcutaneous tissue for a period of several days. The aim of this article is to describe the layout and constituents of a novel glucose sensor and the rationale behind the measures that were used to optimize its performance. In order to a...
متن کاملA MEMS viscometric sensor for continuous glucose monitoring
We present a MEMS sensor aiming to enable continuous monitoring of glucose levels in diabetes patients. The device features a magnetically-driven vibrating microcantilever, which is situated in a microchamber and separated from the environment by a semi-permeable membrane. Glucose sensing is based on affinity binding principles using a solution of dextran concanavalin-A (Con A) as the sensing f...
متن کاملContinuous blood glucose monitoring with a thin-film optical sensor.
BACKGROUND We recently described a holographic optical sensor with improved selectivity for glucose over fructose that was based on a thin-film polymer hydrogel containing phenylboronic acid receptors. The aim of the present work was to measure glucose in human blood plasma as opposed to simple buffers and track changes in concentration at a rate mimicking glucose changes in vivo. METHODS We ...
متن کاملA Microfabricated Dielectric Affinity Sensor for Continuous Glucose Monitoring
We present a microfabricated affinity sensor using permittivity measurement for continuous glucose monitoring (CGM). This device is based on a perforated electrode separated from a bottom electrode on a substrate by a solution of a synthetic glucose-sensitive polymer. Glucose permeates through the perforated electrode and binds with the polymer, leading to a change in the polymer solution permi...
متن کاملAccuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor.
OBJECTIVE This study evaluated the performance and acceptability of the Enlite(®) glucose sensor (Medtronic MiniMed, Inc., Northridge, CA). SUBJECTS AND METHODS Ninety adults with type 1 or type 2 diabetes wore two Enlite sensors on the abdomen and/or buttock for 6 days and calibrated them at different frequencies. On Days 1, 3, and 6, accuracy was evaluated by comparison of sensor glucose va...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Diabetes Science and Technology
سال: 2017
ISSN: 1932-2968,1932-2968