Accuracy of megavolt radiation dosimetry using thermoluminescent lithium fluoride
نویسندگان
چکیده
منابع مشابه
Radiation dose in balloon dacryocystoplasty: a study using Rando phantoms and thermoluminescent dosimetry.
PURPOSE The radiation dose to the lens of the eye, skin, thyroid and brain of patients who underwent diagnostic and interventional radiological procedures of the lacrimal drainage system have been measured with thermoluminescent dosimeters (TLD-100 and TLD-700) by using an adult male and female Rando phantom. All dose values for one second of fluoroscopic exposure and one frame of digital subtr...
متن کاملPercentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry
The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF:Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical alg...
متن کاملRadiation protection in CT pelvis in Fantoma Rando by thermoluminescent dosimetry.
This paper presents results of equivalent dose organ determining to both primary beam and scattered radiation in a computed tomography (CT) procedures. All measurements were carried out to abdomen and critical organ (gonads) area. Selected dosimeters showed a standard deviation of 4.1% below to the reference values established by international guide lines. The equivalent dose in gonads was 14.2...
متن کاملCompton profile measurements of lithium fluoride with 662 keV radiation
The isotropic Compton profile of lithium fluoride has been deduced from Compton scattering measurements on poly crystalline sample at gamma ray source energy of 662 keV. Here we report the experimental and theoretical Compton profile of lithium fluoride. We calculated directional Compton profile and their anisotropic effect using self-consistent Hatree-Fock wave functions employed on the linear...
متن کاملCalculation of Correction Factors for Dosimeters Thermoluminescent of Lithium Fluoride (LiF-100) for Use in 6MV Photon Beams
Since the beginning of its use, radiation has already presented harm, justifying the necessity of controlled use. In order to monitor its effects and even avoid them, dosimetry has arisen. For the purpose of ensured all the necessary safety and monitor areas where there is radiation use, a lot of devices able to identify and quantify many types of radiation were developed. However, some these d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1977
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00001369558