Advanced control strategy of DFIG during symmetrical grid fault
نویسندگان
چکیده
<p>This article proposes a novel scheme to improve the doubly-fed induction generator (DFIG) behavior during grid fault. The DFIG’s are sensitives voltage variations when abrupt of wind velocity arrive. For enhancing DFIG behavior, protecting converters, and smoothing fluctuations power output under sag voltage; hybrid energy storage system its controller proposed. main advantages our approach faster response suppressing overvoltage on DC bus globally less stress in system. control structure decreases tiredness battery restores rapidly, operating time increases. results obtained by simulations MATLAB validate benefits suggested control.</p>
منابع مشابه
Coordinated Control Strategy for a Hybrid Wind Farm with DFIG and PMSG under Symmetrical Grid Faults
This paper presents a coordinated control strategy for a hybrid wind farm with doubly-fed induction generator (DFIG)and direct-driven permanent-magnet synchronous generator (PMSG)-based wind turbines under symmetrical grid faults. The proposed low-voltage ride-through (LVRT) strategy is based on a novel current allocation principle and is implemented for individual DFIGor PMSG-based wind turbin...
متن کاملSustainable operation and performance improvement of grid connected DFIG during symmetrical faults using fuzzy controller based enhanced field oriented control
According to modern grid regulations, doubly fed induction generator (DFIG) needs to operate without losing synchronism during grid faults. But, severe fault leads to rise in stator and rotor current to a higher value and generator will get damaged. Large oscillations in stator real and reactive power are produced and consequently large torque oscillations get developed. To overcome the above a...
متن کاملStudy on Fault Current of DFIG during Slight Fault Condition
In order to ensure the safety of DFIG when severe fault happens, crowbar protection is adopted. But during slight fault condition, the crowbar protection will not trip, and the DFIG is still excited by AC-DCAC converter. In this condition, operation characteristics of the converter have large influence on the fault current characteristics of DFIG. By theoretical analysis and digital simulation,...
متن کاملPerformance Analysis of Grid connected Wind Energy Conversion System with a DFIG during Fault Condition
Integration of wind turbine based on doubly fed induction generator (DFIG) into the electrical grid has become an important part of electrical generation in many countries and its importance is continuing to increase. A few of them are various speed generations, the decoupled control of active and reactive power and high power capacity. The current and future wind power situation is modeled as ...
متن کاملDFIG Driven Wind Turbine Grid Fault-Tolerance Using High-Order Sliding Mode Control
This research note deals with grid fault-tolerance of a doubly-fed induction generatorbased wind turbine using high-order sliding mode control. Indeed, it is proposed to assess the main and attractive features of high-order sliding modes which are robustness against external disturbances (e.g. grid) and chattering-free behavior (no extra mechanical stress on the drive train). Simulations using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Power Electronics and Drive Systems
سال: 2021
ISSN: ['2722-2578', '2722-256X']
DOI: https://doi.org/10.11591/ijpeds.v12.i3.pp1422-1430