Alagille Syndrome and Repeat Oxygenator Failure during Cardiopulmonary Bypass: A Word of Caution

نویسندگان

چکیده

Alagille syndrome is an autosomal dominant disorder that caused by heterozygous mutation of JAG1 or NOTCH2 gene impacts several multisystem organs including but may not be limited to the liver, heart, musculoskeletal, skin, and eyes. The most common congenital heart defect associated with multilevel right ventricular outflow tract obstruction multiple central peripheral branch pulmonary arterial stenoses occurring in up two-thirds these patients. We report two cases who underwent extensive rehabilitation experienced unusual oxygenator failure during cardiopulmonary bypass (CPB). present lessons learned from changes we implemented our practice facilitated smooth conduct CPB other performed subsequently.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scavenging anesthetic gas from a membrane oxygenator during cardiopulmonary bypass.

Concerns remain about the acute and chronic effects on personnel of waste anesthetic gases in the operating room environment. This study demonstrates a simple and effective means of scavenging waste anesthetic gases when halogenated anesthetics are administered through the pump oxygenator during cardiopulmonary bypass. This technique safeguards workers' health by reducing ambient anesthetic lev...

متن کامل

Partial cardiopulmonary bypass in rats using a hollow fibre oxygenator.

Despite new minimally invasive techniques, cardiopulmonary bypass (CPB) is still necessary for many major operations in the field of cardiac surgery. Unwanted side effects of CPB are well known but poorly understood. We therefore developed a rodent model to study the pathophysiology of these potential complications. Male Fischer rats were anaesthetized, intubated and ventilated. The carotid art...

متن کامل

Successful management of membrane oxygenator failure during cardiopulmonary bypass--the importance of safety algorithm and simulation drills.

With a high risk to time ratio, the advent of cardiopulmonary bypass has facilitated greater advances in technical procedures in cardiac surgery. This, however, has not come without its own complication risk and previous near misses have been reported with regard to various technical aspects of the cardiopulmonary bypass circuit. We present a case of a failed membrane oxygenator and discuss the...

متن کامل

Electrical failure during cardiopulmonary bypass: a critical moment

Electrical failure during cardiopulmonary bypass is a crisis situation for the cardiac surgical team. Fortunately, it has a low incidence with low morbidity and mortality rates. Notwithstanding, institutional preventative and management measures should be taken. Here, we report a case of electrical failure during cardiopulmonary bypass, which was successfully managed during the surgery, allowin...

متن کامل

Oxygenator exhaust capnography for prediction of arterial carbon dioxide tension during hypothermic cardiopulmonary bypass.

Continuous monitoring and control of arterial carbon dioxide tension (P(a)CO2) during cardiopulmonary bypass (CPB) is essential. A reliable, accurate, and inexpensive system is not currently available. This study was undertaken to assess whether the continuous monitoring of oxygenator exhaust carbon dioxide tension (PexCO2) can be used to reflect P(a)CO2 during CPB. A total of 33 patients under...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The journal of extra-corporeal technology

سال: 2022

ISSN: ['0022-1058']

DOI: https://doi.org/10.1051/ject/202254338