Amperometric-type NOx sensor based on YSZ electrolyte and La-based perovskite-type oxide sensing electrode
نویسندگان
چکیده
منابع مشابه
A GdAlO3 Perovskite Oxide Electrolyte-Based NOx Solid-State Sensor
NOx is a notorious emission from motor vehicles and chemical factories as the precursor of acid rain and photochemical smog. Although zirconia-based NOx sensors have been developed and showed high sensitivity and selectivity at a high temperature of above 800 °C, they fail to show good performance, and even don't work at the typical work temperature window of the automotive engine (<500 °C). It...
متن کاملNovel Measuring Method for Detection of Propene Using Zirconia-Based Amperometric Sensor with Oxide-Based Sensing Electrode
An amperometric sensor based on yttria-stabilized zirconia (YSZ) and an oxidebased sensing electrode (SE) was examined for the detection of propene. Among the various oxide-based SEs tested, ZnO (+8.5 wt.% Pt) was found to give good sensitivity and selectivity to C3H6 at 600°C. A novel measuring method named “pulsed-potential method” was adopted here to obtain improved sensing characteristics. ...
متن کاملElectronic conduction in La-based perovskite-type oxides
A systematic study of La-based perovskite-type oxides from the viewpoint of their electronic conduction properties was performed. LaCo0.5Ni0.5O3±δ was found to be a promising candidate as a replacement for standard metals used in oxide electrodes and wiring that are operated at temperatures up to 1173 K in air because of its high electrical conductivity and stability at high temperatures. LaCo0...
متن کاملZIRCONIA-BASED GAS SENSORS USING OXIDE SENSING ELECTRODE FOR MONITORING NOx IN CAR EXHAUST
Solid-state electrochemical sensors using yttria-stabilized zirconia (YSZ) and oxide sensing electrode (SE) were fabricated and examined for NOx detection at high temperatures. Among various single-oxide SEs examined, NiQSE for the mixed-potential-type NOx sensor was found to exhibit rather high sensitivity to N@ even in the high temperature range of 800900°C. This sensor showed quicker respons...
متن کاملHighly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Ceramic Society of Japan
سال: 2010
ISSN: 1882-0743,1348-6535
DOI: 10.2109/jcersj2.118.180