An Electron Beam Spectrum Monitor Using Synchrotron Light
نویسندگان
چکیده
منابع مشابه
Slc Energy Spectrum Monitor Using Synchrotron Radiation’
The SLAC Liiac is being upgraded for the use in the SLAC Linear Collider (SLC). The improved Linac must accelerate electron and positron bunches from 1.2 GeV to 50 GeV while producing output energy spectra of about 0.2 %. The energy spectra must be maintained during operation to provide for good beam transmission and to minimize chromatic effects in the SLC ARCs and Find Focus. The energy spect...
متن کاملScanning Electron Beam Profile Monitor
A scanning beam profile monitor is described that was developed for use along the Stanford two-mile linear accelerator. The maximum beam loss due to scattering caused by this monitor can be made to be a small fraction of that which would be caused by a Cerenkov radiator or scintillating screen. (To be submitted to the Review of Scientific Instruments) * Work supported by the U. S. Atomic Energy...
متن کاملSynchrotron Light Monitor System for Nsls-ii
A visible synchrotron light diagnostic beam line has been designed at the NSLS2 storage ring, using the dipole radiation. The ‘cold-finger’ configuration has been selected to block the central x-rays. Beam power on the first mirror is less than 1W, no water cooling is required for the in-vacuum mirror. The beam line layout and major applications will be discussed in this paper. Two vacuum ports...
متن کاملBeam-size Measurements on Pep-ii Using Synchrotron-light Interferometry
PEP-II transverse profiles are measured by imaging visible synchrotron light from dipoles in the two rings. The images are broadened by surface errors on the primary extraction mirrors, which have a complex design due to high beam currents. To improve vertical beam-size measurements, we installed a synchrotron-light interferometer, following Mitsuhashi at KEK. In a two-slit interferometer, fine...
متن کاملMeasurements of Photon Beam Flattening Filter Using an Anisotropic Analytical Algorithm and Electron Beam Employing Electron Monte Carlo
Introduction: This study aimed to report the measurement of photon and electron beams to configure the Analytical Anisotropic Algorithm and Electron Monte Carlo used in clinical treatment. Material and Methods: All measurements were performed in a large water phantom using a 3-dimensional scanning system (PTW, Germany). ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1979
ISSN: 0018-9499
DOI: 10.1109/tns.1979.4330014