Aortic input impedance in man: acute response to vasodilator drugs.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic input impedance in man: acute response to vasodilator drugs.

In 18 patients who underwent coronary arteriography, aortic velocity and pressure data were obtained during a control state and during either isoproterenol infusion at 1, 2 and 3 micrograms/min or graded nitroprusside infusion (average peak dose 60 micrograms/min). Impedance moduli and phase angles were derived to 10 Hz for controls states, isoproterenol at 2 micrograms/min, and at peak nitropr...

متن کامل

Aortic input impedance in normal man: relationship to pressure wave forms.

The relationship between the shape of the ascending aortic pressure wave form and aortic input impedance was studied in 18 patients who underwent elective cardiac catheterization but in whom no heart disease was found. Ascending aortic flow velocity and pressure were simultaneously recorded from a multisensor catheter with an electromagnetic velocity probe and a pressure sensor mounted at the s...

متن کامل

Aortic input impedance in infants and children.

Flow and pressure measurements were performed in the ascending aortas of six pediatric patients ranging in age from 1 to 4 yr and in weight from 7.2 to 16.4 kg. From these measurements, input impedance was calculated. It was found that total vascular resistance decreased with increasing patient weight and was approximately one to three times higher than those of adults. Conductance per unit wei...

متن کامل

Aortic input impedance in heart failure.

The input impedance of the systemic circulation was calculated from recordings of pulsatile pressure and flow in the ascending aorta of 20 patients. Ten patients had clinical and hemodynamic evidence of heart failure. The other 10 subjects had no clinical evidence of heart failure and were used as a control group. In the heart failure patients, both input resistance and characteristic impedance...

متن کامل

Role of aortic input impedance in the decreased cardiovascular response to exercise with aging in dogs.

The diminished cardiac output response to exercise with advancing age may be attributable to intrinsic inability of the old ventricle to respond appropriately and/or to an additional loading imposed upon the ventricle by the aged vascular system. The steady (resistance) and pulsatile (characteristic impedance) load components together comprise the vascular load faced by the ejecting ventricle. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Circulation

سال: 1981

ISSN: 0009-7322,1524-4539

DOI: 10.1161/01.cir.63.6.1305