Application of a fast proton dose calculation algorithm to a thorax geometry
نویسندگان
چکیده
منابع مشابه
Application of a fast proton dose calculation algorithm to a thorax geometry.
Treatment planning in proton therapy requires the calculation of absorbed dose distributions on beam shaping components and the patient anatomy. Analytical pencil-beam dose algorithms commonly used are not always accurate enough. The Monte Carlo approach is more accurate but extremely computationally intensive. The Fast Dose Calculator, a track-repeating algorithm, has been proposed as an alter...
متن کاملA simplified Monte Carlo algorithm considering large‐angle scattering for fast and accurate calculation of proton dose
PURPOSE The purpose of this study is to improve dose calculation accuracy of the simplified Monte Carlo (SMC) algorithm in the low-dose region. Because conventional SMC algorithms calculate particle scattering in consideration of multiple Coulomb scattering (MCS) only, they approximate lateral dose profiles by a single Gaussian function. However, it is well known that the low-dose region spread...
متن کاملdesigning a fast locking pll
a phase-locked loop (pll) based frequency synthesizer is an important circuit that is used in many applications, especially in communication systems such as ethernet receivers, disk drive read/write channels, digital mobile receivers, high-speed memory interfaces, system clock recovery and wireless communication system. other than requiring good signal purity such as low phase noise and low spu...
Dosimetric accuracy of tomotherapy dose calculation in thorax lesions
BACKGROUND To analyse limits and capabilities in dose calculation of collapsed-cone-convolution (CCC) algorithm implemented in helical tomotherapy (HT) treatment planning system for thorax lesions. METHODS The agreement between measured and calculated dose was verified both in homogeneous (Cheese Phantom) and in a custom-made inhomogeneous phantom. The inhomogeneous phantom was employed to mi...
متن کاملFast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model
The highly conformal dose distributions produced by scanned proton pencil beams (PBs) are more sensitive to motion and anatomical changes than those produced by conventional radiotherapy. The ability to calculate the dose in real-time as it is being delivered would enable, for example, online dose monitoring, and is therefore highly desirable. We have previously described an implementation of a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiation Measurements
سال: 2010
ISSN: 1350-4487
DOI: 10.1016/j.radmeas.2010.05.022