Assessment of ventilation inhomogeneity during mechanical ventilation using a rapid-response oxygen sensor-based oxygen washout method

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of ventilation inhomogeneity during mechanical ventilation using a rapid-response oxygen sensor-based oxygen washout method

PURPOSE Ventilatory inhomogeneity indexes in critically ill mechanically ventilated patients could be of importance to optimize ventilator settings in order to reduce additional lung injury. The present study compared six inhomogeneity indexes calculated from the oxygen washout curves provided by the rapid oxygen sensor of the LUFU end-expiratory lung volume measurement system. METHODS Inhomo...

متن کامل

Oxygen uptake during weaning from mechanical ventilation.

Total body oxygen uptake (VO2) increases during the transition from machine-assisted ventilation to spontaneous breathing. Since the volume of oxygen consumed by the respiratory muscles must contribute to the increase in VO2 (delta VO2), we explored whether delta VO2 and/or measurements of respiratory power output (Wresp) provide clinically useful information in the evaluation of disease state ...

متن کامل

Oxygen toxicity during artificial ventilation.

Repeated pulmonary collapse and changes suggestive of a severe alveolar-capillary diffusion defect were observed over a period of 20 days in a patient who was receiving artificial ventilation because of status epilepticus. Profound cyanosis followed attempts to discontinue assisted ventilation. The Bird Mark 8 respirator employed was found to be delivering approximately 90% oxygen on the air-mi...

متن کامل

Oxygen consumption with mechanical ventilation in a field anesthesia machine.

Field anesthesia machines (FAM) with gas-powered ventilators have been developed for remote locations that may not have a central supply of oxygen. These ventilators may rapidly deplete oxygen cylinders, especially in patients with decreased pulmonary compliance. Our goal in this study was to determine oxygen consumption rates with a contemporary FAM in models of high (HC) and low (LC) pulmonar...

متن کامل

The impacts of prone position on the blood oxygen saturations and heart rates of preterm infants under the mechanical ventilation

Background: The methods of baby's position are an important critical factor in ventilation and oxygenation of tissues. Although the prone position as one of the recommended position has beneficial effect on the development of premature infants, little research has been done. Methods: In a clinical trial among mechanically ventilated infants, hospitalized in the neonatal intensive care units (N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Intensive Care Medicine Experimental

سال: 2014

ISSN: 2197-425X