Biomechanical evaluation of a bipedicular spinal fixation device: three different strength tests
نویسندگان
چکیده
منابع مشابه
Biomechanical evaluation of a biomimetic spinal construct
BACKGROUND Laboratory spinal biomechanical tests using human cadaveric or animal spines have limitations in terms of disease transmission, high sample variability, decay and fatigue during extended testing protocols. Therefore, a synthetic biomimetic spine model may be an acceptable substitute. The goal of current study is to evaluate the properties of a synthetic biomimetic spine model; also t...
متن کاملComparison of three different fixation constructs for radial neck fractures: a biomechanical study
BACKGROUND Fixation of radial neck fractures can be achieved with a plate and screw construct or with two screws. This study evaluated the biomechanical properties of three different fixation methods following radial neck fractures. METHODS Twenty-four fourth-generation composite radii were sawed to simulate an unstable radial neck fracture. They were then instrumented with a plate and screw ...
متن کاملBiomechanical evaluation of periprosthetic femoral fracture fixation.
BACKGROUND A variety of methods are available for the fixation of femoral shaft fractures after total hip arthroplasty. However, few studies in the literature have quantified the performance of such repair constructs. The aim of this study was to evaluate biomechanically four different constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. METH...
متن کاملHuman Bone strength Evaluation through different Mechanical Tests
Bone mineral density [BMD] generally correlates with bone strength. BMD testing is used to assess bone density and diagnose osteoporosis. The correlation between CT numbers and mechanical property estimated from cortical bone were found to be low (r2<0.2) and cancellous bone were found to be higher (r2>0.6). The specific relationship depending on the types of bone, that predict elastic module f...
متن کاملBiomechanical analysis of the FlatWire Figure 8 sternal fixation device.
OBJECTIVE To determine whether the FlatWire Figure 8 sternal fixation device (Penn United, USA) is mechanically superior to the current standard in sternotomy closure. DESCRIPTION Unstable sternal closure using traditional steel-wire cerclage can increase postoperative pain, bony cut-through and wound dehiscence. The authors present the Figure 8 sternal fixation device to minimize these compl...