Biomechanical evaluation of a bipedicular spinal fixation device: three different strength tests

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical evaluation of a biomimetic spinal construct

BACKGROUND Laboratory spinal biomechanical tests using human cadaveric or animal spines have limitations in terms of disease transmission, high sample variability, decay and fatigue during extended testing protocols. Therefore, a synthetic biomimetic spine model may be an acceptable substitute. The goal of current study is to evaluate the properties of a synthetic biomimetic spine model; also t...

متن کامل

Comparison of three different fixation constructs for radial neck fractures: a biomechanical study

BACKGROUND Fixation of radial neck fractures can be achieved with a plate and screw construct or with two screws. This study evaluated the biomechanical properties of three different fixation methods following radial neck fractures. METHODS Twenty-four fourth-generation composite radii were sawed to simulate an unstable radial neck fracture. They were then instrumented with a plate and screw ...

متن کامل

Biomechanical evaluation of periprosthetic femoral fracture fixation.

BACKGROUND A variety of methods are available for the fixation of femoral shaft fractures after total hip arthroplasty. However, few studies in the literature have quantified the performance of such repair constructs. The aim of this study was to evaluate biomechanically four different constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. METH...

متن کامل

Human Bone strength Evaluation through different Mechanical Tests

Bone mineral density [BMD] generally correlates with bone strength. BMD testing is used to assess bone density and diagnose osteoporosis. The correlation between CT numbers and mechanical property estimated from cortical bone were found to be low (r2<0.2) and cancellous bone were found to be higher (r2>0.6). The specific relationship depending on the types of bone, that predict elastic module f...

متن کامل

Biomechanical analysis of the FlatWire Figure 8 sternal fixation device.

OBJECTIVE To determine whether the FlatWire Figure 8 sternal fixation device (Penn United, USA) is mechanically superior to the current standard in sternotomy closure. DESCRIPTION Unstable sternal closure using traditional steel-wire cerclage can increase postoperative pain, bony cut-through and wound dehiscence. The authors present the Figure 8 sternal fixation device to minimize these compl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Spine Journal

سال: 2003

ISSN: 0940-6719,1432-0932

DOI: 10.1007/s00586-002-0520-9