Calibration method for rotating-analyzer ellipsometers

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration method for rotating-analyzer ellipsometers

One of the main sources of errors in ellipsometry is inaccurate calibration; if the plane of incidence is not known correctly, all azimuthal angles of the optical components involved, such as the polarizer, the analyzer, and sometimes the compensator, contain errors. Thus calibration errors proliferate, leading ultimately to errors in the measured quantities A and *. Not withstanding the fact t...

متن کامل

An Improved Calibration Method for a Rotating 2D LIDAR System

This paper presents an improved calibration method of a rotating two-dimensional light detection and ranging (R2D-LIDAR) system, which can obtain the 3D scanning map of the surroundings. The proposed R2D-LIDAR system, composed of a 2D LIDAR and a rotating unit, is pervasively used in the field of robotics owing to its low cost and dense scanning data. Nevertheless, the R2D-LIDAR system must be ...

متن کامل

Rotating analyzer–fixed analyzer ellipsometer based on null type ellipsometer

The theory and design of an inexpensive rotating analyzer unit is presented, which allows a conventional null type ellipsometer to work as rotating analyzer–fixed analyzer automatic ellipsometer, without sacrificing the possibility to work in null mode. The mode switching is performed simply by adding or removing the rotating analyzer from its holder. It is shown that the rotating analyzer phas...

متن کامل

Calibration of Area-Reduction Empirical Method for Dam Reservoir

The mathematical model of Area-Reduction empirical method is written through MATLAB software. Three periods of the hydrologic survey are required to run, calibrate and validatethe model. The Dez Dam, which is one of the most significant dams of the Middle East with three periods of hydrographic surveys in 1972, 2002 and 2011, has been chosen for the investigation. The annual average of the inpu...

متن کامل

Calibration of a Metallic Access Network Analyzer

A calibration approach is proposed to compensate the systematic errors when the input reflection coefficient of a metallic access network cable is obtained using single port measurements from an access network analyzer. The analyzer is a versatile instrument and uses optimal cable matching and internal balancing to achieve maximum measurement resolution. The analyzer uses test-leads connected t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Optical Society of America A

سال: 1988

ISSN: 1084-7529,1520-8532

DOI: 10.1364/josaa.5.001466