Calibration of the power-recycled gravitational wave detector, GEO 600

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of the dual - recycled GEO 600 detector for the S 3 science run

1 Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut) und Universität Hannover, Außenstelle Hannover, Callinstr. 38, 30167 Hannover, Germany 2 Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ, UK 3 Max-Planck-Institut für Gravitationsphysik, Albert-Einstein-Institut, Am Mühlenberg 1, 14476 Golm, Germany 4 Department of Physics and Astronomy, Cardiff University, PO...

متن کامل

GEO 600: building a gravitational wave observatory

An international network of laser-interferometric gravitational wave detectors is nearing the end of the main commissioning phase and will soon enter into an extended observational period, collecting data for a duration of order one year. This article outlines the construction, design and commissioning of the GEO 600 gravitational wave observatory. GEO 600 is a laserinterferometric gravitationa...

متن کامل

Feedforward correction of mirror misalignment fluctuations for the GEO 600 gravitational wave detector

Abstract The core instrument of the GEO 600 gravitational wave detector is a Michelson interferometer with folded arms. The five main optics that form this interferometer are suspended in vacuum by triple pendulums with quasimonolithic lower stages of fused silica. After installation of these pendulums in early 2003, a larger than expected coupling of longitudinal ground motion to tilt misalign...

متن کامل

A photon pressure calibrator for the GEO 600 gravitational wave detector

Interferometer mirror displacement induced by radiation pressure is used to demonstrate an alternative calibration method for the GEO 600 detector. The photon calibrator utilizes an amplitude modulated laser diode with up to 1.4 W output power at a wavelength of 1035 nm. The achieved accuracy of the strain amplitude calibration is dominated by the laser power calibration error, which is in the ...

متن کامل

Preparing GEO 600 for gravitational wave astronomy—a status report

A number of gravitational wave detectors throughout the world are currently moving from the final stages of commissioning to a more continuous observational mode. Together, these detectors form a global network which will search for gravitational waves from various astrophysical sources, such as continuous wave signals from rotating neutron stars, transient signals from, for example, inspiralli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2003

ISSN: 0034-6748,1089-7623

DOI: 10.1063/1.1597959