Clinical Accuracy of a Continuous Glucose Monitoring System With an Advanced Algorithm
نویسندگان
چکیده
منابع مشابه
Accuracy of a new real-time continuous glucose monitoring algorithm.
BACKGROUND Through minimally invasive sensor-based continuous glucose monitoring (CGM), individuals can manage their blood glucose (BG) levels more aggressively, thereby improving their hemoglobin A1c level, while reducing the risk of hypoglycemia. Tighter glycemic control through CGM, however, requires an accurate glucose sensor and calibration algorithm with increased performance at lower BG ...
متن کاملThe accuracy of a new real-time continuous glucose monitoring algorithm: an analysis.
In this issue of Journal of Diabetes Science and Technology, Keenan and colleagues used archival data from the STAR 1 clinical trial (Medtronic Diabetes) to support the claim that the new Veo calibration algorithm improves the accuracy of continuous glucose monitoring, particularly in the critical hypoglycemic range. Extensive data analyses are presented to support this claim; the results are c...
متن کاملAccuracy of the SEVEN continuous glucose monitoring system: comparison with frequently sampled venous glucose measurements.
BACKGROUND The purpose of this study was to compare the accuracy of measurements obtained from the DexCom SEVEN system with Yellow Springs Instrument (YSI) laboratory measurements of venous blood glucose. METHODS Seventy-two subjects with insulin-requiring diabetes, aged 18-71, were enrolled in a multicenter, prospective single-arm study. All participants wore the SEVEN continuous glucose mon...
متن کاملToward a Continuous Intravascular Glucose Monitoring System
Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. ...
متن کاملThe accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes.
OBJECTIVE To evaluate the accuracy and precision of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes. RESEARCH DESIGN AND METHODS In 30 children with type 1 diabetes (mean age 11.2 +/- 4.1 years), the Navigator glucose values were compared with reference serum glucose values of blood samples obtained in an inpatient clinical research center and mea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Diabetes Science and Technology
سال: 2014
ISSN: 1932-2968,1932-2968
DOI: 10.1177/1932296814559746