Coracoid bone graft osteolysis after Latarjet procedure: A comparison study between two screws standard technique vs mini-plate fixation
AIMS One of the reason for Latarjet procedure failure may be coracoid graft osteolysis. In this study, we aimed to understand if a better compression between the coracoid process and the glenoid, using a mini-plate fixation during the Latarjet procedure, could reduce the amount of coracoid graft osteolysis. MATERIALS AND METHODS A computed tomography scan analysis of 26 prospectively followed...
متن کاملEfficacy and outcome of open reduction and internal fixation with mini-plate in ulnar coronoid process fractures
Aim: This study aimed to investigate clinical efficacy of open reduction and mini-plate fixation for the ulnar coronoid process fractures. Methods: 21 cases of ulnar coronoid process fractures treated with open reduction and mini-plate fixation were enrolled. Causes of injury included traffic injuries in 4 cases and fall on the ground in 17 cases. There were 10 cases of type I, 9 cases of type ...
متن کاملMini-Open Latarjet Procedure for Recurrent Anterior Shoulder Instability
Anterior shoulder instability is a common problem. The Latarjet procedure has been advocated as an option for the treatment of anteroinferior shoulder instability. The purpose of this paper is to explain our surgical procedure titled "Mini-open Latarjet Procedure." We detailed patient positioning, skin incision, subscapularis approach, and coracoid fixation. Then, we reviewed the literature to ...
متن کاملMini-plate fixation versus suture suspensory fixation in cervical laminoplasty
BACKGROUND Both the mini-plate fixation and suture suspensory fixation techniques are extensively applied in cervical laminoplasty, but which technique is superior has not been ascertained. The purpose of this meta-analysis is to compare the results between mini-plate fixation and suture suspensory fixation in cervical laminoplasty for the patients with multilevel cervical compressive myelopath...
متن کاملSS and titanium mini plate fixation in fracture of mandible
INTRODUCTION The development and application of bone plating to the maxillofacial skeleton has revolutionized the operative management of trauma and reconstructive surgery. Non compression monocortical miniplate fixation of the mandible is an accepted and reliable method for providing semi rigid internal fixation. In the 21 st century many other systems have been introduced such as locking plat...