Closed-loop focal plane wavefront control with the SCExAO instrument
نویسندگان
چکیده
منابع مشابه
Fast & Furious focal-plane wavefront sensing.
We present two complementary algorithms suitable for using focal-plane measurements to control a wavefront corrector with an extremely high-spatial resolution. The algorithms use linear approximations to iteratively minimize the aberrations seen by the focal-plane camera. The first algorithm, Fast & Furious (FF), uses a weak-aberration assumption and pupil symmetries to achieve fast wavefront r...
متن کاملFOCAL POINT AND FOCAL K-PLANE
This paper deals with the basic notions of k-tautimmersions . These notions come from two special cases; that is, tight and taut immersions. Tight and taut based on high and distance functions respectively and their basic notions are normal bundle, endpoint map, focal point, critical normal. We generalize hight and distance functions to cylindrical function and define basic notions of k-taut ...
متن کاملAdaptive Wavefront-Correction Algorithms Using Focal-Plane Array Intensity Measurements
Earth’s atmospheric turbulence induces aberrations in the wavefront of the optical signal from a distant spacecraft. These aberrations cause diffusion and spreading of the signal energy in the receiver’s focal plane, potentially resulting in an increase in bit-error rate (BER) by several orders of magnitude when significant background radiation is present, such as during daytime operation. The ...
متن کاملClosed loop adaptive optics for microscopy without a wavefront sensor.
A three-dimensional wide-field image of a small fluorescent bead contains more than enough information to accurately calculate the wavefront in the microscope objective back pupil plane using the phase retrieval technique. The phase-retrieved wavefront can then be used to set a deformable mirror to correct the point-spread function (PSF) of the microscope without the use of a wavefront sensor. ...
متن کاملClosed Loop Control
Background The purpose of this study was to evaluate electrode temperatures obtained using a radiofrequency ablation system that incorporates closed loop feedback control to achieve preset target electrode temperatures and to determine if closed loop temperature control results in a lower incidence of developing a coagulum. Methods and Results Two hundred seventy patients underwent catheter abl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Astronomy & Astrophysics
سال: 2016
ISSN: 0004-6361,1432-0746
DOI: 10.1051/0004-6361/201628496