Closed-loop focal plane wavefront control with the SCExAO instrument

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast & Furious focal-plane wavefront sensing.

We present two complementary algorithms suitable for using focal-plane measurements to control a wavefront corrector with an extremely high-spatial resolution. The algorithms use linear approximations to iteratively minimize the aberrations seen by the focal-plane camera. The first algorithm, Fast & Furious (FF), uses a weak-aberration assumption and pupil symmetries to achieve fast wavefront r...

متن کامل

FOCAL POINT AND FOCAL K-PLANE

This paper deals with the basic notions of k-tautimmersions . These notions come from two special cases; that is, tight and taut immersions. Tight and taut based on high and distance functions respectively and their basic notions are normal bundle, endpoint map, focal point, critical normal. We generalize hight and distance functions to cylindrical function and define basic notions of k-taut ...

متن کامل

Adaptive Wavefront-Correction Algorithms Using Focal-Plane Array Intensity Measurements

Earth’s atmospheric turbulence induces aberrations in the wavefront of the optical signal from a distant spacecraft. These aberrations cause diffusion and spreading of the signal energy in the receiver’s focal plane, potentially resulting in an increase in bit-error rate (BER) by several orders of magnitude when significant background radiation is present, such as during daytime operation. The ...

متن کامل

Closed loop adaptive optics for microscopy without a wavefront sensor.

A three-dimensional wide-field image of a small fluorescent bead contains more than enough information to accurately calculate the wavefront in the microscope objective back pupil plane using the phase retrieval technique. The phase-retrieved wavefront can then be used to set a deformable mirror to correct the point-spread function (PSF) of the microscope without the use of a wavefront sensor. ...

متن کامل

Closed Loop Control

Background The purpose of this study was to evaluate electrode temperatures obtained using a radiofrequency ablation system that incorporates closed loop feedback control to achieve preset target electrode temperatures and to determine if closed loop temperature control results in a lower incidence of developing a coagulum. Methods and Results Two hundred seventy patients underwent catheter abl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Astronomy & Astrophysics

سال: 2016

ISSN: 0004-6361,1432-0746

DOI: 10.1051/0004-6361/201628496