Combined Thickness and Permittivity Measurement of Thin Layers with Open-Ended Coaxial Probes
نویسندگان
چکیده
منابع مشابه
Measurement of Complex Permittivity of Large Concrete Samples with an Open-Ended Coaxial Line
A 70 mm-open-ended coaxial line probe was developed to perform measurements of the dielectric properties of large concrete samples. The complex permittivity was measured in the frequency range 50 MHz – 1.5 GHz during the hardening process of the concrete. As expected, strong dependence of water content was observed.
متن کاملOpen-ended coaxial-line permittivity measurements on pulverized materials
The open-ended, coaxial-line probe technique can be used to obtain estimates of the pennittivities of some solid dielectrics over broad ranges of frequency by measurements on powdered or pulverized samples, but certain limitations must be recognized. Such a probe was used with a network analyzer to estimate the permittivities of coal and limestone from reflection coefficients measured on pulver...
متن کاملThe Measurement of Dielectric Properties of Liquids at Microwave Frequencies Using Open-ended Coaxial Probes
Significant progress has been made in recent years in the development of microwave tomographic imaging systems for medical applications. In order to design an appropriate microwave imaging system for industrial applications, and to interpret the images produced, the materials under imaging need to be characterised. In this paper, we describe the use of open-ended coaxial probes for the measurem...
متن کاملMeasurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part II -- Experimental Results
A new S-band waveguide technique has been developed for the calibration of miniature probes used in determining electric fields in biological tissues at 2.45 GHz. A section of waveguide is filled with tissue-eqnivalent liquid separated from the air-filled wavegoide by a very thin (0.25-mm) planar dielectric spacer. The probe response is measured as a function of position on each side of the spa...
متن کاملPermittivity Measurements of Biological Samples by an Open-ended Coaxial Line
We previously reported on the complex permittivity and dc conductivity of waste-activated sludge. The measurements, spanning a frequency range of 3 MHz to 40 GHz, were made using an open-ended coaxial transmission line. Although this technique is well established in the literature, we found that it was necessary to combine methods from several papers to use the open-ended coaxial probe to relia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2019
ISSN: 1424-8220
DOI: 10.3390/s19081765