Combining Load Sensors and a Robotic Arm to Balance TKA : Clinical Results at One Year

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Balance 1 year after TKA: correlation with clinical variables.

Knee osteoarthritis results in changes that affect balance. It has been reported that osteoarthritis worsens proprioception and increases the risk of falling. The objective of this study was to assess changes in balance among patients with knee osteoarthritis at 1 year after total knee arthroplasty (TKA) surgery and its relationship with clinical variables. This prospective, observational study...

متن کامل

An LPV Approach to Sensor Fault Diagnosis of Robotic Arm

One of the major challenges in robotic arms is to diagnosis sensor fault. To address this challenge, this paper presents an LPV approach. Initially, the dynamics of a two-link manipulator is modelled with a polytopic linear parameter varying structure and then by using a descriptor system approach and a robust design of a suitable unknown input observer by means of pole placement method along w...

متن کامل

Invariance Property in One - Link Robotic Arm

In the study of eignefrequencies of robotic arms versus load, straightforward invariance property is singled out under a preload condition. We show that compliance does not affect this effect. This property opens the way to new robust and finite dimensional controllers. KEY WORDS—flexible arm, compliance, eigenfrequencies, infinite dimensional systems

متن کامل

Control of a 2-DoF robotic arm using a P300-based brain-computer interface

In this study, a novel control algorithm, based on a P300-based brain-computer interface (BCI) is fully developed to control a 2-DoF robotic arm. Eight subjects including 5 men and 3 women perform a 2-dimensional target tracking in a simulated environment. Their EEG (Electroencephalography) signals from visual cortex are recorded and P300 components are extracted and evaluated to perform a real...

متن کامل

One-year clinical results after epi-LASIK for myopia.

PURPOSE To evaluate the clinical results of epi-LASIK for the treatment of low to moderate myopia and myopic astigmatism. DESIGN Retrospective, noncomparative, interventional case series. PARTICIPANTS Two hundred thirty-four eyes of 138 patients underwent epi-LASIK for the correction of low to moderate myopia. Mean preoperative spherical equivalent ranged from -1.0 to -7.25 diopters (D) (-3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of ISAKOS

سال: 2023

ISSN: ['2059-7762', '2059-7754']

DOI: https://doi.org/10.1016/j.jisako.2023.03.183